Page 22
XLT 020111
Condensation
Water Leaking, Front
The WhisperKOOL product is designed to dissipate excessive moisture by collecting it in the compressor 
pan and using a heating element to remove condensation. Operating the WhisperKOOL in excessively 
humid  conditions  can  cause  the  unit  to  accumulate  more  condensation  (water)  then  the  unit  can 
dissipate while operating, resulting in leakage. In order to resolve this issue, the unit is designed with 
both a Condensate Evaporator control switch and an external drain line (see page 13). The Condensate 
Evaporator  switch  will  allow  you  to  operate  the  heating  element  continuously  whether  the  unit  is 
operating or not. (See Condensate Evaporator on page 13.)
Icing Up
Icing  up  can  occur  if  the  airflow  through  the  coil  is  limited  or  obstructed  by  any  type  of  cover  or 
obstruction, such as racking & bottles in front of unit. In the unlikely event that your WhisperKOOL unit 
is icing up in front, unplug the unit for 24 to 36 hours and allow the ice to melt away (collect liquid in 
pan to avoid damaging racks). Check to see if bottle probe is securely in the bottle. Plug the unit back 
in and test on the by-pass plug for 24 hours (refer to page 21 and 26). Clean the front and back coils 
before retesting. Within the 24 hour period the unit should not develop ice and should be generating 
cold air. If the unit is functioning properly when on by-pass, the icing may have been a result of a faulty 
thermostat (see page 21). If while on by-pass, the unit continues to form ice, first check that all 4 fans 
are working. Secondly, check to see if the unit is blowing cold air. If the air is cool to lukewarm, but not 
cold, the unit requires further service. Do not allow your unit to continue running if ice appears on your 
coil. This can create warm air to be released from unit.
Please contact Customer Service for assistance and guidelines. Before contacting Customer Service, see 
pages 24-28.
Power Requirements
When the WhisperKOOL starts to operate, it draws several times more power (amps) during the start-up 
cycle  than  it  does  during  normal  operation.  Make  sure  you  have  the WhisperKOOL  on  a  dedicated 
electrical  line  at  a  minimum  of  20  amps.  See  the  Product  Information Table  on  page  10  to  find  the 
correct amperage requirement for your unit. Make sure that the power line for the WhisperKOOL does 
not have any additional equipment installed on that circuit. An extra load on the line may be drawing 
power away from the WhisperKOOL unit. In some cases it may not be readily apparent that an additional 
appliance or electrical device has been installed on the circuit breaker. In addition, the unit may not be 
used  on  an  electrical  line  with  a  Ground  Fault  Interrupter  (GFI).  The  WhisperKOOL  will  draw  more 
amperage than the GFI will allow with the exception of the ducting kit.
Drainline 
Daily use of your Wine Cellar Cooling System can cause debris to clog the condensation line. When your 
unit’s condensation line becomes clogged, it can cause the condensation to back up into your unit and 
your cellar. It is recommended to replace a clogged drainline.