SERVICE (cont.)
CONTROL THERMOSTAT
FIG. 8 CONTROL THERMOSTAT
P2143.35
Location:
 
 The control thermostat is located inside hood on 
the right side.
Test Procedures:
1.   Disconnect the brewer from the power source.
2.   Locate the blue/black wire on the control thermo-
stat.
3.   With a voltmeter, check the voltage across the blue 
wire on the control thermostat and the white or 
red wire on the tank heater. Connect the brewer 
to the power source. The indication must be:
 
a) 120 volts ac for 2-wire 120 volt models. 
 
b) 208 volts ac for 3-wire 120/208 volt models.
 
c) 240 volts ac for 3-wire 120/240 volt models.
4.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the wir-
ing diagrams and check the brewer wiring harness.
5.  Locate the black wire on the control thermostat.
6.  Gently remove the capillary bulb and grommet 
 
from the tank.
7.  With a voltmeter, check the voltage across the 
black wire of the control thermostat and the white 
or red wire on the tank heater when the control 
thermostat is turned fully clockwise. Connect the 
brewer to the power source. The indication must 
be:
 
a) 120 volts ac for 2-wire 120 volt models.
 
b) 208 volts ac for 3-wire 120/208 volt models.
 
c) 240 volts ac for 3-wire 120/240 volt models.
8.   Disconnect the brewer from the power source.
If voltage is present as described, reinstall the capillary 
tube into the tank to the line 5.5" above the bulb, the 
control thermostat is operating properly.
If voltage is not present as described, replace the 
thermostat. 
Removal and Replacement:
1.  Remove both wires from the control thermostat 
terminals.
2.  Remove the thermostat capillary bulb by firmly 
pulling up on the capillary tube at the tank lid.  This 
will disengage the grommet from the tank lid.
3.  Remove the #8-32 screw holding the control 
thermostat to its bracket.
4.  Slide the grommet to the line 5.5" above the bulb 
on the new capillary tube.
5.  Insert the capillary bulb through the hole in the 
tank lid and press the grommet firmly and evenly 
so that the groove in the grommet fits into the tank 
lid.
6.  Carefully bend the capillary tube so that the tube 
and bulb inside the tank are in a vertical position.
NOTE – The capillary tube must be clear of any electri-
cal termination and not kinked.
7.  Fasten the new control thermostat to its bracket.
8.  Refer to Fig. 9 when reconnecting the wires.
9.  Adjust the control thermostat as required.
FIG. 9 CONTROL THERMOSTAT TERMINALS
4
2
3
1
MINUT
ES
MINUTE
S
BU
NN-O-MATI
C
P/N  05791-0006 120 V
AC
5
3
6
4
7
5
6
6
7
8
BUNN
OFF
HI
BUNN
OFF
HI
BLK to Tank Heater
BLU to Limit Thermostat 
P2090.80