ITT ICS 用户手册

下载
页码 32
8
3 HP Only
  Pump  Suction NPT  Discharge NPT 
X  *Wt. Max.
  1
 
1¼-5 
1¼ 
7.35 .94 3.01 4.62  17
 
 
x 1½-5 
1½ 
1¼ 
7.22  1.06  2.88
 
4.56
 
17
  
  Motor 
Weights
 
HP 
Single Phase 
 
  Three Phase   
C Max. Length
  
ODP 
TEFC  ODP TEFC 
X-Proof
 3 
40 
45 
42  37  — 
13.34
Dimensions in inches, weight in pounds.
Dimensions and Weights – Determined by Pump
58317
CF–8M
1
.59
SINGLE PHASE ONL Y
5.31
MAX.
7.10
MAX.
5.88
1.5
1
.5
L
1
4
 NPT (OPTIONAL)
2.88
3.38
SUCTION
DISCHARGE
W
C
MAX.
SLOT .34 WIDE
X .88     TO
CL
CL
5.28 3HP 1 PHASE ONLY
3.50
X
3.50
.19
2.44
2.44
6.50
4.88
MAX.
R
Available Motor Dimensions and Weights
½ HP – 2 HP
2.50
58317
CF–8M
1
.59
SINGLE PHASE ONL Y
6.31
MAX.
6.50
2.50
L
1
4
 NPT (OPTIONAL)
2.88
3.38
SUCTION
DISCHARGE
W
C
MAX.
.41 DIA HOLES
4 PLACES,
3.50
X
4.12
2.94
2.94
6.75
4.88
MAX.
R
2.66
  Pump  Suction NPT  Discharge NPT 
X  *Wt. Max.
  1
 
x 1¼-5 
1¼ 
3.75  .94 
3.01  4.62 
17
 
 
x 1½-5 
1½ 
1¼ 
3.62  1.06  2.88
 
4.56
 
17
Dimensions and Weights – Determined by Pump
  
 
  Motor 
Weights
 
HP 
 
Single Phase   
 
Three Phase
   
ODP TEFC EXP  ODP TEFC EXP
 
½
 
 
16 21 47 19 18 27 
9
15
16
 
¾  19 24 41 21 21 30 10¼
 
 
1  22 26 49 23 21 30 11
 1½
 
 28 35 56 27 27 37 
11
5
16
 
 
2  33 39 60 32 33 44 
12
1
16
 
Available Motor Weights and Dimensions
NOTES:
1.  Pumps will be shipped with top vertical discharge as standard, for other  
  orientations, remove casing bolts,rotate to desired position, and tighten 
3
8
" bolts  
  to 24 lbs.-ft.
2.  Dimensions in inches, weight in pounds.
3.  Not to be used for construction purposes unless certifi ed.
4.  Motor dimensions may vary with motor manufacturers.
* Weight is liquid end only. For complete pump, add weight of applicable 
motor.
C Max.
Length
ICS – Engineering Data