INSTALLATION REQUIREMENTS
These instructions are intended as a general guide only for use by 
qualified persons and do not supersede any national or local 
codes in any way. Compliance with all local, state or national 
codes pertaining to this type of equipment should be determined 
prior to installation.
Read this entire instruction manual as well as instructions 
supplied with separate equipment before starting the installation.
The installation of the whole house dehumidifier must conform to 
the requirements of the National Fire Protection Association, the 
National Electrical Code, ANSI/NFPA No. 70 (latest edition) in the 
United States, and any state laws, local ordinances (including 
plumbing or wastewater codes). Local authorities having 
jurisdiction should be consulted before installation is made. Such 
applicable regulations or requirements take precedence over the 
general instructions in this manual.
Install the conditioned air plenum, ducts and air filters (not 
provided) in accordance with NFPA 90B Standard for the 
Installation of Warm Air Heating and Air-Conditioning Systems 
(latest edition).
The whole house dehumidifier is designed and approved for 
indoor use only.
It is recommended that the whole house dehumidifier be 
matched to the HVAC system to ensure proper operation and 
efficient performance.
Refer to the rating plates located on the whole house 
dehumidifier and on the HVAC system.
It is recommended that the whole house dehumidifier be 
connected to only one existing HVAC system. If there are multiple 
HVAC systems in the building, use one dehumidifier per system.
Tools and Parts
Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.
Tools Needed
Parts Supplied
Grommet plugs (4)
Parts Needed
Check local codes and HVAC supplier. Check existing electrical 
supply, and read “Electrical Requirements” and “Location 
Requirements” before purchasing parts.
Location Requirements
The dehumidifier may be installed on all new or existing 
furnaces or air handlers used in residential applications. 
The whole house dehumidifier is designed to be located 
indoors.
Locate the whole house dehumidifier as close to the return air 
duct of an existing furnace or air handler as possible to 
minimize the required ductwork for connecting the 
dehumidifier to the existing furnace or air handler. 
The location should allow for access to the filter access panel 
at the front of the dehumidifier for inspection and replacing 
the filter. See the Minimum Clearance Requirements chart.
The location must allow for access to the electrical access 
panel for servicing and maintenance.
Locate the whole house dehumidifier in an area where the 
temperature is between 40ºF (4ºC) and 125ºF (52ºC). If the 
dehumidifier is located in an area of extreme heat or high 
humidity, additional external insulation may be required to 
prevent condensation on the exterior of the dehumidifier.
If the dehumidifier is located above a living area or above an 
area where water leakage may cause damage (see local 
codes for other requirements), a secondary drain pan must 
be installed under the dehumidifier.
The controls for the whole house dehumidifier are remote 
from the dehumidifier and must be located in the space that 
is to be conditioned. The controls are low voltage (24-volt) 
and should be connected to the dehumidifier with code 
approved, low voltage thermostat cable.
If the dehumidifier is located directly on structural building 
members, use vibration absorbers/eliminators.
Locking pliers
Drill and drill bit
Screwdriver
Tin snips
Sheet metal screws 
or rivets
Shop-fabricated sheet 
metal turning vanes, 
offsets, and transitions, 
if needed
Sealant
Insulated flexible duct
³⁄₈"-16 all-thread rod for 
suspended applications
Insulated duct for fresh air 
ventilation
Minimum Clearance Requirements
For Optimum Service Access
Front
24"
Rear
12"
Blower End
12"
Top
12"