World Marketing of America KWN195 用户手册

下载
页码 25
11
Figure 17 - Pilot
OPERATING  YOUR  HEATER
n
LIGHTING
n
INSTRUCTIONS
1 .     S TO P !     R e a d       t h e     s a f e t y
     information  on  the  side of
       heater.
2.  Check  that  gas  supply  to
       heater  is  on.
3.  Push  in  gas  control  knob
       slightly  and  turn  clockwise   
      to the OFF position.
NOTE
:   Knob  cannot  be  turned from
“PILOT”  to  “OFF”  unless knob  is
p u s h e d     i n     s l i g h t l y .   D o     n o t
force.
4.   Wait five (5) minutes  to  clear
      out   any   air. Then   smell  for
       gas,  including  near  the  floor.
        If      you      smell     gas,    STOP!
       Follow   “B”     in     the     safety
        information  on  the  side of  the
       heater.  If   you   do   not   smell
       gas,  go  to  the  next  step.
5.    Push     in    gas   control   knob
        slightly                  and                 turn
       counterclockwise       
             to
      “PILOT/IGN”  and  depress  for
        five(5) seconds
NOTE
:   The  first  time  that  the
h e a t e r       i s     o p e r a t e d     a f t e r
connecting  the  gas  supply ,  the
control  knob  should  be  depressed
for  about  thirty (30) seconds.  This
will   allow  air  to  bleed   from  the  gas
system.
6.    With  control  knob  pressed  in,
       push  down  and   release   the
     ignitor button. This  will  light
       pilot. If needed,  keep  pressing
     ignitor button until pilot  lights.
NOTE
:  If  pilot  does  not  stay  lit,
refer  to  
Troubleshooting
,  pages
14  through  16.   Also  contact  a
qualified  service person  or  gas
supplier   for   repairs.  Until   repairs
are   made,   light   pilot   with   match.
To  light  pilot  with  match, see
Manual   Lighting   Procedure.
7.   Keep  control  knob  pressed  in
     for  thirty  (30)  seconds  after
       lighting       pilot.         After       30
       seconds,  release  control  knob.
If   control   knob  does   not   pop
     up  when  released,  contact  a
      qualified     service    person    or
       gas  supplier  for  repairs.
NOTE
:   If  pilot  goes  out,  repeat
steps 3 through 7. Wait one (1)
minute  before  lighting  pilot  again
8.   Turn             control            knob
       counterclockwise      
          to
      desired    heating    level.   The
      main  burner  should  light.  Set
      control  knob  to  any  heat  level
       between  HI  and  LO.
n
TO TURN OFF
n
GAS TO APPLIANCE
Shutting  Off  Heater
1.   Turn  control  knob  clockwise
         
  to  the  OFF  position.
2.     Turn  off  all   electric   power   to
       the  appliance  if  service  is  to
        be  performed.
SHUTTING OFF BURNER ONLY
(PILOT STAYS LIT)
Turn control knob clockwise 
to  the  PILOT/IGN  position.
n
MANUAL LIGHTING
n
PROCEDURE
1.     Remove  lower  front    panel   (see
        Figure 7 page 7).
2.   Follow   steps   1   through  5
        under 
Lighting Instructions
.
3.     With   control   knob   pressed  in,
        strike    match.    Hold   match    to
        pilot until pilot lights.
4.     Keep  control  knob  pressed  in
      for 30  seconds  after lighting
        pilot.  After  30  seconds, release
      control   knob.  Follow   step  8
        under  
Lighting  Instructions
.
5.     Replace  lower  front   panel.
Figure 16 - Control  Knob  In  The  OFF
Position
Figure 18 - Burner  Patterns
Manual Control Models