Wilton 15HH 用户手册

下载
页码 40
 
10
This machine must be grounded. Grounding 
provides a path of least resistance to help divert 
current away from the operator in case of 
electrical malfunction. 
Make sure the voltage of your power supply 
matches the specifications on the motor plate of 
the machine. 
Extension Cords 
The use of an extension cord is not 
recommended for this machine, but if one is 
necessary make sure the cord rating is suitable 
for the amperage listed on the machine's motor 
plate. An undersize cord will cause a drop in line 
voltage resulting in loss of power and 
overheating. 
The chart in Figure 11 shows the correct size 
cord to use based on cord length and motor 
plate amp rating. If in doubt, use the next 
heavier gauge. The smaller the gauge number 
the heavier the cord. 
Adjustments
 
Tools required for assembly: 
10, 12 and 17mm open-end wrenches 
3, 5 and 6mm hex wrenches 
0.2” (0.5mm) feeler gauge 
straight edge 
gauge block 
cross-point screwdriver 
    
  Disconnect machine from 
power source before making any 
adjustments (except feed rate).
 
Belt Tension 
Inspect the tension of the belts frequently during 
the first few times you use the planer. Belts often 
stretch during this trial period. If they require 
tightening, proceed as follows: 
1.  Remove the belt guard and the rear panel.  
2. Loosen the bottom nut on the motor 
adjustment screw (Figure 12) with a 17mm 
wrench. 
3.  Turn the top nut on the adjustment screw to 
lower the motor plate, which will increase 
the belt tension. 
4.  Proper tension is achieved when there is 
slight deflection in the belt midway between 
the pulleys, using moderate finger pressure. 
5.  Tighten the bottom nut on the adjustment 
screw (Figure 12). 
Recommended Gauges (AWG) of Extension Cords 
Extension Cord Length *  
Amps 
25 
feet 
50 
feet 
75 
feet 
100 
feet 
150 
feet 
200 
feet 
5  16 16 16 14 12 12 
to 
8  16 16 14 12 10 NR 
to 
12  14 14 12 10 NR NR 
12 
to 
15 12 12 10 10 NR NR 
15 to 20 
10 
10 
10 
NR 
NR 
NR 
21 
to 
30  10  NR NR NR NR NR 
 
*based on limiting the line voltage drop to 5V at 150% of the 
rated amperes. 
NR: Not Recommended.
 
Figure 11 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 12