Wilson WAM-5500-375/500 用户手册

下载
页码 12
      2 
SM-165 
1.  KNOW YOUR POWER TOOL. Read this service manual carefully. 
2.  GROUNDING INSTRUCTIONS. This product is equipped with a cord having an 
equipment-grounding conductor and a grounding plug. The plug must be plugged 
into an appropriate outlet that is properly installed and grounded in accordance 
with all local codes and ordinances. 
3.  KEEP GUARDS IN PLACE and in working order. 
4.  KEEP WORK AREA CLEAN. Cluttered areas and benches invite accidents. 
5.  AVOID DANGEROUS ENVIRONMENT. Keep work areas well lit. 
6.  STORE IDLE TOOLS. When not in use, tools should be stored in dry, high or 
locked-up place – out of reach of children. 
7.  DON’T FORCE TOOLS. It will do the job better and safer at the rate for which it 
was designed. 
8.  USE RIGHT TOOLS. Don’t force small tool or attachment to do the job of a 
heavy-duty tool. 
9.  WEAR PROPEL APPAREL. No loose clothing or jewelry to get caught in mov-
ing parts. Rubber gloves and footwear are recommended when working outdoors. 
10.  USE SAFETY GLASSES with most tools. Also face or dust mask if cutting op-
eration is dusty. 
11.  DON’T ABUSE CORD. Never carry tool by cord or yank it to disconnect from 
receptacle. Keep cord from heat, oil and sharp edges. 
12.  SECURE WORK. Use clamps or a vise to hold work. It’s safer than using your 
hands to operate tool. 
13.  DON’T OVERREACH. Keep proper footing and balance at all times. 
14.  MAINTAIN TOOL WITH CARE. Keep tools sharp and clean for best and safest 
performance. Follow instructions for lubricating and changing accessories. 
15.  DISCONNECT TOOLS:  When not in use; before servicing; when changing ac-
cessories such as blades, bits, cutters, etc. 
16.  REMOVE ADJUSTING KEYS AND WRENCHES. Form habit of checking that 
keys and adjusting wrenches are removed from tool before turning it on. 
17.  AVOID ACCIDENTAL STARTING. Don’t carry plugged-in tool with finger or 
switch. 
18.  Remove the plug from the socket before carrying out any adjustment, servicing or 
maintenance. 
19.  Do not use unit with combustible fluids or where combustible fluids or fumes may 
be present.  
 
 
READ AND UNDERSTAND ALL INSTRUCTIONS 
Failure to follow all instructions listed below, may result in 
accident, fire and/or personal injury. 
SAVE THESE INSTRUCTIONS 
 
WARNING!
  
SAFETY INSTRUCTIONS 
 
 
   
 
 
    11 
SM-165 
TROUBLE–SHOOTING 
PROBLEM 
CAUSE & SOLUTION 
•  No power 
•  Green Light not lit up when 
unit is first plugged into power 
outlet 
•  GFCI Plug not reset 
—press reset button on GFCI 
•  GFCI Plug defective 
•  Power cord defective 
•  Green Light (Power On) defective 
•  Power up but motor not turning 
when activated 
•  Blown Fuse 
—replace fuse #1 
•  Defective motor 
•  Defective wiring in unit 
•  Overload protection engaged on the mo-
tor 
—reset the motor by pressing OLP reset but-
ton from the back of the unit. (use the hole 
next to the fan)  
•  Motor running but Flexible 
Shaft not turning 
•  Broken Safety Coupling 
•  Broken Shaft Cable 
•  Motor running but no water 
output at  end of Flexible Shaft 
•  Water supply not turn on 
•  Defective Solenoid Valve 
•  Flexible Shaft turning but not 
feeding out 
•  Feed wheel not grabbing the shaft 
•  Broken belt 
•  Brush head is getting resistance from 
inside the tube 
—Reverse couple of inches and feed forward 
•  Motor running and water drips 
inside unit 
Note: Some water coming back 
from the rotating brush that is col-
lected inside the Feeder Gun Assem-
bly will come out from under the 
unit. There are 4 drainage holes for 
this water to drain out of the control 
unit. 
•  Worn Teflon seal inside Motor Connec-
tor 
•  Leakage in tube or  tube fittings 
•  Unit running rough and/or 
noisy 
•  Lack of lubrication in Motor Connector 
—grease ball bearings inside Motor Connec-
tor  
—replace worn or corroded ball bearings in 
Motor Connector 
•  Loose Covers on the unit 
•  Power up but motor not turning 
forward when activated 
•  Stop switch plate damaged and is con-
stantly hitting the forward stop switch.