1.  Failure to turn off electric or main gas sup-
ply to heating system could cause personal 
injury and/or property damage by shock, gas 
suffocation, fire, and/or explosion.
2.  Do not use this control on circuits exceeding
specified voltage. Higher voltage will dam-
age the control and may cause shock or fire
hazard.
3.  NEVER USE FLAME OR ANY KIND OF SPARK 
TO CHECK FOR GAS LEAKS–COULD CAUSE 
FIRE AND/OR EXPLOSION.
4.  DO NOT USE WIRE JUMPER on any pilot 
systems, such as standing pilot, proven/in-
termittent pilot, or spark-to-pilot ignition–a 
fire and/or explosion may result.
If you do not follow these instructions exactly, a fire or explosion
may result, causing property damage, personal injury or loss of life.
5.  Do not use a control set for natural gas with
LP gas, or a control set for LP gas with natural
gas. Personal injury and/or property damage, 
gas suffocation, fire, and/or explosion may
result.
6.  Do  not  use  a  gas  valve  which  appears  to
be damaged. A damaged valve may cause  
personal injury and/or property damage 
due  to  shock,  gas  suffocation,  fire  and/or
explosion. Contact supplier to replace any
valve that appears to have been damaged.
7.  Do not use a gas valve that has been in direct 
contact with water. Water entering gas valve
may result in concealed internal damage to 
gas valve. Personal injury and/or property 
damage, gas suffocation, fire and/or explo-
sion may result.
WARNING
!
DO NOT BEGIN INSTALLATION UNTIL YOU READ THE FOLLOWING 
PRECAUTIONS.
WARNING
!
Properly install gas piping to control. 
•  Do not remove protective inlet or outlet caps until ready to connect supply pipe to gas valve.
•  Use new supply pipe, properly threaded, reamed, de-burred, and cleaned.
•  Use backup wrench, applied only to provided wrench flats on inlet boss, when tightening the
supply pipe. Do not grip bracket, solenoid or any other part of control.
•  Do not over-tighten pipe to control (
50 ft-lbs max.)
•  Always install sediment trap in the gas supply line to prevent contamination of gas valve.
Failure to install properly can cause gas leakage resulting in injury due to fire or explosion.
CAUTION
!
1.  Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring
can cause equipment damage, property damage, and/or personal injury.
2.  This control is not intended for use in locations where it may come in direct contact with water.
Suitable protection must be provided to shield the control from exposure to water (dripping,
spraying, rain, etc.). 
3.   Clean gas piping of contaminants, cutting fluid, or other chemicals which might react harm-
fully with the gas valve components before install.
 