Rane Wheelchair TF 410 产品宣传页

下载
页码 2
TF 407 & TF 410
MA 3 TRANSFORMER KITS
All features & specifications subject to change without notice DOC 103209
©Rane  Corporation    10802  47th  Ave.  W.,    Mukilteo  WA  98275-5098    TEL  425-355-6000    FAX  425-347-7757    WEB  www.rane.com
9. Once the transformers are securely mounted, lay the unit down (never leave the unit 
standing on its end unattended).
10. See Figure 3. The + (hot) jumper must be cut when a transformer is installed. The 
– (gnd) jumper may be cut for a fully isolated secondary or left in for a ground 
referenced secondary. There are two wire jumpers for each Channel:
 
Ch 1 
+ (hot) W6 
– (gnd) W9 
 
Ch 2 
+ (hot) W8 
– (gnd) W10 
 
Ch 3 
+ (hot) W13 
– (gnd) W14
11. Cut the required jumper(s).
12. Locate the BLK/WHT primary pair. Twist the wires together.
13. Connect the BLK primary wire:
 
Ch 1: J8 
Ch 2: J15 
Ch 3: J25
14. Connect the WHT primary wire:
 
Ch 1: J20 
Ch 2: J11 
Ch 3: J22
15. Locate the BLK/RED secondary pair. Twist the wires together.
16. Connect the BLK secondary wire:
 
Ch 1: J10 
Ch 2: J14 
Ch 3: J21
17. Connect the RED secondary wire:
 
Ch 1: J9 
Ch 2: J16 
Ch 3: J17
18. Use the supplied tie raps to “dress” wires along the rear of the chassis and away 
from power transformer and circuit board.
19. Place the supplied Label on the outside of MA 3 to indicate the location and type 
of transformer installed.
20. Re-install the top cover.
Gently lay capacitors back toward the rear
Ch 1      Ch 2       Ch 3
Figure 3. Jumpers