Raymarine Wind & Close Hauled Wind Instrument ST60 用户手册

下载
页码 52
Chapter 3: Installation
25
Power supply connections
SeaTalk systems
CAUTION:  
When instruments are connected to SeaTalk, ensure that the 
power supply for the SeaTalk 12 V line is protected by a 5 A fuse.
Systems with a large number of instruments on the SeaTalk bus may require 
connections to the power supply from each end of the system (‘ring-main’ style), 
to maintain sufficient voltage throughout the system.
This requirement depends on the total length of the cable run and the total 
number of instruments in the system, as follows:
Cable run
No. of instruments
Power connections
Up to 10 m
13 maximum
26 maximum
1
2
Up to 20 m
7 maximum
13 maximum
1
2
D4345-2
Blue
Red
Green
Yellow
Screen
Cable from Rotavecta 
Cable from Wind Vane
SeaTalk cable
SeaTalk cable
Connections to ST60 Wind instrument
Blue
Red