Yamaha XMV8280/XMV8140/XMV8280-D/XMV8140-D 业主指南

下载
页码 42
Operations
XMV8280/XMV8140/XMV8280-D/XMV8140-D Owner’s Manual
24
Parameter Operations
*2: “XY” means “operate X, and then operating Y.” For example, “[SELECT] A  encoder” means that you should press the [SELECT] 
A, and then operate the encoder.
To do this...
Operating mode 
(indication)
Operation
Description
Changing the attenuator 
value (volume)
attenuator
(ATT)
[SELECT] (of the channel to 
be changed)  encoder 
*2
The [SELECT] indicator of the selected channel 
will lit, and the attenuator value can be edited by 
the encoder.
The range of adjustment is -99 dB–0 dB in 1 dB 
steps.
Changing the polarity
polarity
(POL)
[SELECT] (of the channel to 
be changed)  encoder 
*2
The [SELECT] indicator of the selected channel 
will light, and the polarity can be changed by using 
the encoder.
Changing the high pass fil-
ter (HPF) cutoff frequency
Turning off the high pass 
filter (HPF)
HPF
(HPF)
[SELECT] (of the channel to 
be changed)  encoder 
*2
The [SELECT] indicator of the selected channel 
will light, and the high pass filter (HPF) on/off set-
ting and cutoff frequency can be changed by using 
the encoder. This will be set to 80 Hz if a high 
impedance connection is specified; it will be turned 
OFF if a low impedance connection is specified.
In order to protect the amplifier, the HPF of the 
selected channel cannot be turned OFF if a high 
impedance connection is specified.
Switching between analog/
digital input
analog/digital input 
selection
(SRC)
Encoder operation
Use the encoder to change the analog/digital input 
selection. This selection applies to all channels.
Do not select “analog” if your audio network has 
been configured using the [YDIF] connectors or 
Dante [PRIMARY]/[SECONDARY] connectors.
Selecting “analog” will interrupt audio transmission 
to and from the devices that are connected via the 
YDIF connectors or Dante connectors.
Switching whether the 
[SIGNAL] indicators are 
used for input or for output
[SIGNAL] indicator 
switching
(SIG)
Encoder operation
Use the encoder to specify whether the [SIGNAL] 
indicators will show the input signal level or the out-
put signal level.
Digital input sensitivity 
selection
digital input 
sensitivity
(DIS)
Encoder operation
Use the encoder to change the digital input sensi-
tivity setting. To prevent inadvertent setting, the 
value does not change right away when the 
encoder is turned. Until the input sensitivity 
changes, “
– – –
” appears in the display.
Indication
Polarity
NOR
Normal polarity
INV
Inverted polarity
Indication
Meaning
OFF
HPF is off
H40
Cutoff frequency is 40 Hz
H80
Cutoff frequency is 80 Hz
Indication
Input connectors
ANA
Analog input connectors
DIG
[YDIF] connectors 
(XMV8280/XMV8140)
Dante [PRIMARY]/
[SECONDARY] connectors
(XMV8280-D/XMV8140-D)
Indication
Lit condition
IN
Input
OUT
Output
Indication
Input sensitivity
D20
0 dB
D03
+17 dB
– – –
(value in process of being 
changed)