VXi VT1422A 用户手册
Programming the VT1422A & VT1529A/B for Remote Strain Measurement 69
Connecting the VT1529A/B to Strain Gages
The following discussion relates to the connection marked "C" in Figure 3-1
on page 58. Connecting the strain gages to the RJ-45 telecom connectors is
illustrated below. These connections can be made with the same type of
cable and crimp-on connectors used for Data Interface connection
(connection "A" in Figure 3-1). See Figure 3-8 for a gage connection example.
on page 58. Connecting the strain gages to the RJ-45 telecom connectors is
illustrated below. These connections can be made with the same type of
cable and crimp-on connectors used for Data Interface connection
(connection "A" in Figure 3-1). See Figure 3-8 for a gage connection example.
Channel Connector
Pin-to-Signal
Relationship
Figure 3-9 shows the pin-to-signal relationship for each VT1529A/B strain
gage connector. The same signal names are found on the following strain
bridge configuration illustrations as well.
gage connector. The same signal names are found on the following strain
bridge configuration illustrations as well.
Figure 3-8. VT1422A to Strain Gage Connection
RJ-45 Modular Connector (Shielded)
8-Conductor Twisted-Pair, Overall-Shielded
(Probably Stranded for Flexability)
(Example Half-Bridge Connection)
Figure 3-9. Pin-out for Strain Gage Connectors
Shield Gnd
Excitation
Excitation Sense
Shield Gnd
Pinout for Lower Connector Row
Excitation Sense
Sense
Excitation
R Cal
R Cal
+
-
Sense
-+
- +
-
-
+
Shield Gnd
Pinout for Upper Connector Row
Shield Gnd
3
2
1
4 5 6 7 8
6
5
4
2
1
3
8
7
Sense
Sense