Viking Technology Technology Computer Drive PSF1XXXXGXXXX 用户手册

下载
页码 60
 
 
 
Manual 
1/2/2014 
PSFS1XXXXGXXXX 
Viking Technology 
Revision B7 
 
Page 43 of 60 
www.vikingtechnology.com
 
 
 
 
5.1.9.2 
Supported Baseline Attribute Details 
The table below provides a detailed description of supported S.M.A.R.T. 
attributes and how they may be used. 
 
Table 5-6: Baseline S.M.A.R.T. Attribute Details 
ID 
Attribute Name 
Description 
Rational 
Raw Read Error 
Rate 
Raw error rate related to ECC errors. 
Errors are counted as ECC errors 
above a threshold. For the 
CONTROLLER, this attribute  
includes Uncorrectable ECC (UECC) 
errors, and Uncorrectable RAISE 
(URAISE)errors.  
 
Normalized Equation:  
10log10(BitsRead/ReadErrors + 1)  
SectorsRead= Number of sectors read  
SectorsToBits= 512*8  
BitsRead= SectorsRead*SectorsToBits  
 
Normalized Value Range:  
Best = 100  
Worst = 1  
Invalid = 0  
 
Raw Usage
The Raw Read error rate 
includes two types of ECC errors 
that are tracked by the 
CONTROLLER: UECC and 
URAISE. The normalized 
equation for Raw read error rate 
is logarithmic since the valid 
BER range of the attribute spans 
from 1.00E-10 to 1.00E-12. To 
force positive numbers, the 
numerator and denominator  
are flipped. One is then added to 
the number of errors in the 
denominator to avoid a  
divide-by-0 condition if no errors 
are encountered. By taking the 
log of the inverted BER and 
multiplying by ten a reasonable  
range of normalized values from 
120 to 38 (representing a BER 
range of 1.00E-13 to 1.68E-04 ) 
are presented.  
 
This Attribute reads ‘0’ until a 
sample size between 10E10 and 
10E12 is available to be  
tracked by this Attribute.  
:  
[3-0] : Number of sectors read  
[6-4]: Read errors (UECC+URAISE)