Utica Boilers MGB Series II/MGC Series 安装指导

下载
页码 28
19
11 - LIGHTING INSTRUCTIONS
LIGHTING PROCEDURE FOR BOILER WITH 
INTERMITTENT PILOT SYSTEM
A.  This appliance is equipped with an ignition device which 
automatically lights the pilot. Do not try to light the 
appliance by hand.
CAUTION
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switches; do not use 
any phone in your building.
• Immediately call your gas supplier from a 
neighbor’s phone. Follow the gas supplier’s 
instructions. 
• If you cannot reach your gas supplier, call the fire 
department.
!
  
OPERATING INSTRUCTIONS FOR INTERMITTENT 
PILOT SYSTEM
1. 
STOP! Read the safety information to the left.
2. 
Set the thermostat to lowest setting.
3. 
Turn off all electric power to the appliance.
4. 
This appliance is equipped with an ignition device which 
automatically lights the pilot. Do not try to light the 
pilot by hand. 
Figure 16 - Intermittent Pilot
5. 
Turn gas control knob clockwise 
 to “OFF.”
6. 
Wait (5) minutes to clear out any gas. If you then smell 
gas, STOP! Follow “What To Do If You Smell Gas” in the 
safety information to the left. If you don’t smell gas, go 
on to the next step.
7. 
Turn gas control knob counterclockwise 
 to “ON.”
8. 
Turn on all electric power to the appliance.
9. 
Set thermostat to desired setting.
10. 
If the appliance will not operate, follow the instructions 
To Turn Off Gas To Appliance” , and call qualified 
service technician or your gas supplier.
TO TURN OFF GAS TO THE APPLIANCE
1. 
Set the thermostat to lowest setting.
2. 
Turn off all electric power to the appliance if service is 
to be performed.
3. 
Push in gas control knob slightly and turn clockwise  
 to "OFF." DO NOT FORCE.
4. 
Call qualified service technician.
 WARNING
If you do not follow these instructions 
exactly, a fire or explosion may result 
causing property damage, personal injury 
or loss of life.
• This appliance is equipped with an ignition device 
which automatically lights burner. Do NOT try to 
light this burner by hand.
• Before operating smell all around appliance area 
for gas. Be sure to smell next to floor because 
some gas is heavier than air and will settle to the 
floor.
• Use only your hand to turn the gas shutoff 
valve. Never use tools. If valve will not turn 
by hand, do not try to repair it, call a qualified 
service technician. Force or attempted repair may 
result in fire or explosion.
• Do not use this appliance if any part has 
been under water. Immediately call a qualified 
service technician to inspect appliance and to 
replace any part of control system and any gas 
control which has been under water.
!
  
NOTICE
Before lighting any type of pilot burner (standing or 
intermittent), verify the hot water boiler and system 
are full of water to minimum pressure of 12 psi in 
the system, also verify system is vented of air. Set 
operating control of thermostat to “below” normal 
setting. Refer to following appropriate lighting 
instruction.