Utica Boilers MGB Series II/MGC Series 安装指导
20
13 - LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above.
2. Set the thermostat to lowest setting.
3. Turn off all electric power to the appliance.
4. This appliance is equipped with an ignition device
2. Set the thermostat to lowest setting.
3. Turn off all electric power to the appliance.
4. This appliance is equipped with an ignition device
which automatically lights the pilot. Do not try to
light the pilot by hand.
OFF
ON
INLET
GAS CONTROL KNOB
PILOT ADJUSTMENT
(UNDER CAP SCREW)
PILOT
OUTLET
OUTLET
WIRING
TERMINALS (2)
INLET
PRESSURE
TAP
TERMINALS
(2)
GROUND
PRESSURE
TAP
PRESSURE REGULATOR ADJUSTMENT
(UNDER CAP SCREW)
OUTLET
5. Remove lower front panel.
6. Rotate the gas control knob clockwise
to
“OFF”.
7. Wait five (5) minutes to clear out any gas. Then
smell for gas, including near the floor. If you smell
gas, STOP!
Immediately call your gas supplier
from a neighbor’s phone. Follow the gas
supplier’s instructions
. If you don’t smell gas,
go to next step.
8. Rotate gas control knob counterclockwise
to
“ON”.
9. Replace lower front panel.
10. Turn on all electric power to the appliance.
11. Set thermostat to desired setting.
12. If the appliance will not operate, follow the
10. Turn on all electric power to the appliance.
11. Set thermostat to desired setting.
12. If the appliance will not operate, follow the
instructions “To Turn Off Gas To Appliance” and call
your service technician or gas supplier.
TO TURN OFF GAS TO APPLIANCE
1. Set the thermostat to lowest setting.
2. Turn off all electric power to the appliance if
1. Set the thermostat to lowest setting.
2. Turn off all electric power to the appliance if
service is to be performed.
3. Push in gas control knob slightly and turn
clockwise
to “OFF” Do not force.
WARNING
If you do not follow these
instructions exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
• This appliance is equipped with an ignition
device which automatically lights burner. Do
NOT try to light this burner by hand.
• Before operating smell all around appliance
area for gas. Be sure to smell next to floor
because some gas is heavier than air and
will settle to the floor.
• Use only your hand to turn the gas
shutoff valve. Never use tools. If valve
will not turn by hand, do not try to repair
it, call a qualified service technician. Force
or attempted repair may result in fire or
explosion.
• Do not use this appliance if any part
has been under water. Immediately call
a qualified service technician to inspect
appliance and to replace any part of control
system and any gas control which has been
under water.
!
LIGHTING PROCEDURE FOR BOILER WITH
INTERMITTENT PILOT SYSTEM
For Your Safety, Read Before Operating!!
A. This appliance is equipped with an ignition device
which automatically lights the pilot. Do not try to
light appliance by hand.
CAUTION
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switches; do not
• Do not touch any electrical switches; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call
the fire department.
!
Figure 15 - Automatic Gas Valve