Base Assembly
300, 400 and 500 boilers are the basic models. 
• 300 model has (6) burners
• 400 model has (8) burners
• 500 model has (10) burners 
Combinations of basic models are used to assemble 600 
through 1500 models. 
Refer to Chart 3 for proper order of assembly. When two or 
more bases are used to assemble boiler, verify tops of bases 
are even. 
1. 
Fasten bases together with 5/16 cap bolts and nuts. 
2. 
Insert two bolts in front posts and two in rear posts as 
shown in Figure 7A 
3. 
After bases are fastened, install base end panels. 
Install end panels before assembling sections. See 
Figure 7B.   
NOTICE
Verify bases are level after assembly.
Section Assembly
1. 
Start sections from left or right end of base. 
2. 
Place end section on base with center-line of section 
directly over joint of base end closure. 
3. 
With boilers having two or more bases, as you progress 
be sure parting line (center-line of section) of intermediate 
sections fall on junction of two bases.  See Figure 8.
Figure #7A
Bolts with nuts in 
the front and rear 
posts
INSTALLATION – ASSEMBLY
Figure 7A
Figure 7B
Alignment 
of section 
along side
Figure 8
Note: First 
Section Alignment 
is critical. Use side 
of base to align 
first section. Do 
not allow side to 
overhang base.