Utica Boilers BC Series II 产品宣传册

下载
页码 2
Utica BC Series II Residential Oil Fired Water Boiler
Dimensional Diagram
Model 
(1)
AHRI Oil Burner 
Input 
(1)
Heating 
Capacity 
Mbh 
(4)
Net AHRI 
Ratings 
(2) (4)
Min. Natural Draft 
Chimney Size
AFUE %
G.P.H.
Mbh
(4)
Water Mbh Round
Square
BC3095
0.95
133
114
99
6”
8”x8”x15’
84.0%
BC4100
1.00
140
121
105
6”
8”x8”x15’
85.0%
BC4115
1.15
161
137
119
6”
8”x8”x15’
84.0%
(1) AHRI burner capacity is based on an oil heating value of 140,000 Btu/gal and with 13% CO
2
.
(2) Net AHRI Water Ratings shown are based on a piping and pickup allowance of 1.15.
(3) Consult manufacturer before selecting boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive 
piping.
(4) For forced hot water heating systems where boiler and all piping are within the area to be heated, select boiler on basis of its Heating Capacity.
General Information 
(See Installation, Operation and Maintenance Manual for complete instructions)
Clearances
Required 
distances 
measured from 
boiler.
Top 
Combustible Materials (Required) 
24” (610 mm)
Left Side (Control Side)
6” (152 mm)
Right Side 
24” (610 mm)
Front 
24” (610 mm)
Back 
6” (152 mm)
Flue Connector
9” (229 mm)
Connections
(All Models)
Return/Supply Tappings
 
1-1/4” NPT, Oil Line 3/8” O.D. copper tubing for runs of 50 feet or less, and ½” 
O.D. for longer runs.
Electrical
120 Volts AC, 60 hertz, 1 phase, Less than 12 amps (15 amp circuit recommended) 
Tankless 
Heater 
Capacities
Model
Input Rate 
G.P.H.
Tankless Heater 
Number
Tankless Heater 
Capacity Intermittent 
Draw G.P.M.
Boiler Water 
Content (Gallons)
BC3095
0.95
L-24
3.25
6.7
BC4100
1.00
3.25
8.2
BC4115
1.15
4.00
8.2
Dimensions/
Weights
Model
(Length of 
Flush Jacket)
(Front of Jacket  
to Center Line  
of Flue Outlet)
(Flue Outlet 
Diameter)
(Tankless 
Coil to Back 
of Jacket)
Weight
BC3095
19”
9-3/4”
6”
8-7/8”
345 lbs.
BC4100
23”
11-3/4”
6”
12-3/4”
404 lbs.
BC4115
23”
11-3/4”
6”
12-3/4”
404 lbs.
Standard 
Equipment
Boiler Controls: High Limit, Circulator Control and Primary Control.
Heat Exchanger: Cast Iron Heat Exchanger with Cast Iron Push Nipples.
Combustion: Beckett Oil Burner, Combustion Chamber with Target Wall/Liner.
Electrical: Wiring Harness, Burner Electrical Disconnect.
Safety: 30 PSI A.S.M.E. Safety Relief Valve.
Other: Crated Cast Iron Boiler with Insulated Flush Jacket; Circulator - 1-1/4”, Temperature Pressure
Gauge, Boiler Drain Valve, 1-1/4” Supply and Return Tapping.
For Tankless Heater Units: Tankless Hot Water Coil and Low Limit.
Options
Taco, Grundfos or Less Pump; Tankless Coil.
Certifications
                                                                
Contractor  
Assistance:
 800.325.5479
P.O. Box 4729 
Utica, New York 13504
tel: 315.797.1310
 
 
fax: 315.797.3762
www.uticaboilers.com
BC Series II 
Front View
BC Series II 
Side View
Maximum Allowable Working  
Pressure 30 psi.
All ratings and specifications subject to change.
PN 240009784 Rev. 2/13
UTB507 BC-SeriesII_SellSheet213.indd   2
2/18/13   12:47 PM