Ultimate Products PF Series 用户手册

下载
页码 44
3
FIG. 2 - WEATHERPROOF BOILERS
* Capacity greater than that requiring testing under F.T.C. regulations.
† For firing rates above 2.00 GPH, consult factory concerning pumping requirements for pool heating
Firing rates of 2.00 gph or less use a Beckett Model AFG oil burner.  Firing rates over 2.00 gph use a Beckett Model CF375 oil burner.
MODEL
HEATING
CAPACITY
MBH
NET I=B=R
RATING
MBH
ANNUAL FUEL
UTILIZATION
EFFICIENCY%
STEADY STATE
EFFICIENCY %
NO.
SEC.
MULTI-PASS
COIL
LENGTH
"A"
DIMENSION
Note 1
Note 2
Note 3
Minimum
.50
59
51
82.9
88.40
Maximum
1.10
123
107
78.2
83.77
3
One
28
1
/ "
Minimum
.95
112
97
82.8
88.25
Maximum
2.10 †
239
208
79.6
85.20
6
One
37
7
/ "
Minimum
1.10
129
112
82.4
88.22
Maximum
2.50 †
294
256
*
*
7
Two
44
3
/ "
Minimum
1.25
147
128
82.7
88.15
Maximum
2.75 †
309
268
*
*
8
One
44
3
/ "
MODEL
HEATING
CAPACITY
MBH
NET I=B=R
RATING
MBH
ANNUAL FUEL
UTILIZATION
EFFICIENCY%
STEADY STATE
EFFICIENCY %
NO.
SEC.
MULTI-PASS
COIL
LENGTH
"A"
DIMENSION
Note 1
Note 2
Note 3
Minimum
.60
71
61
82.9
88.23
Maximum
1.35
151
131
78.6
83.19
4
Less
28
1
/
8
"
Minimum
1.05
124
107
82.9
88.24
Maximum
2.35
276
240
*
*
7
Less
37
7
/
8
"
Minimum
1.35
159
138
82.5
88.26
Maximum
3.00
309
268
*
*
9
Less
44
3
/
8
"
PFO-6T2W
PFO-7TT2W
PFO-8T2W
WEATHERPROOF OIL BOILERS
SPACE HEATERS LESS COIL
RECOMMENDED
FIRING RATES
GPH
PFO-3T2W
SPACE HEATERS LESS COIL
RECOMMENDED
FIRING RATES
GPH
PFO-4W
PFO-7W
PFO-9W