StarTech.com CONYX ECS0016 用户手册

下载
页码 140
Instruction Manual
51
Please note: The ECS0016 requires an external modem attached (via a 
serial cable) to the DB9 port (marked 
Local, located on the front panel).
 
Configure Dial In PPP
To enable dial-in PPP access on the ECS0016 console/modem port:
Select the 
1. 
System: Dial menu option and the port to be configured  
  (Serial DB9 Port or Internal Modem Port).  The ECS0016 console/ 
  modem serial port is set by default to 115200 baud, No parity, 8 data  
  bits and 1 stop bit, with software (XonXoff) flow control enabled. When  
  enabling OoB dial-in on ECS0016 units, it is recommended that this be  
  changed to 
38,4000 baud with Hardware Flow Control.
Select the 
2. 
Baud Rate and Flow Control that will communicate with  
  the modem. You can further configure the console/modem port (e.g. to  
  include modem init strings) by editing /etc/mgetty.config files.
Check the
3. 
 Enable Dial In Access box. 
Enter the 
4. 
User name and Password to be used for the dial-in PPP  
  link. 
In the 
5. 
Remote Address field, enter the IP address to be assigned to  
  the dial-in client. You can select any address for the Remote IP  
  Address, however it and the Local IP Address, must both be in the  
  same network range (e.g. 200.100.1.12 - 200.100.1.67) 
In the 
Local Address field enter the IP address for the Dial-In PPP  
  Server. This is the IP address that will be used by the remote client to  
  access ECS0016, once the modem connection is established. Any  
  address within the IP range of the Remote IP Address can be used  
  (e.g. 200.100.1.12 - 200.100.1.67) addresses must be in the same  
  network range as the Remote IP Address.
The 
Default Route option enables the dialed PPP connection to  
    become the default route for the ECS0016 gateway. 
The 
Custom Modem Initialization option allows a custom AT string  
    modem initialization string to be entered (e.g. AT&C1&D3&K3)