SimpleTech ZeusIOPS 用户手册

下载
页码 84
Zeus
IOPS
 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0
49
W
RITE
 B
UFFER
 C
OMMAND
 (3Bh)
The WRITE BUFFER command is complementary to the READ BUFFER command as a diagnostic 
function for testing logical unit memory in the SCSI target device and the integrity of the service 
delivery subsystem.
Table 26.
Write Buffer Command (3Bh)
The only mode fields supported are:
S
YNCHRONIZE
 C
ACHE
 (10) (35h)
The Logical Block Address and Number of Blocks fields are checked to ensure that the fields are in 
range, but are then ignored and considered set to zero. All outstanding data is written out to the non-
volatile memory. The SYNC_NV and IMMED bits in CDB Byte 1 are ignored.
Bit
Byte
7
6
5
4
3
2
1
0
0
Operation Code (3Bh)
1
Reserved
Mode
2
Buffer ID
3
(MSB)
Buffer Offset
5
(LSB)
6
(MSB)
Parameter List Length
8
(LSB)
9
Control
Mode
Value
Description
5
05h
Download microcode and save.
7
07h
Download microcode with offsets and save.