The fault codes listed in Table 37 indicate that a fault has been detected during the power-on 
sequence. As a result, the unit is in a non-operational state and remedial action is required to replace 
the unit.
Power-on fault codes are indicated as a series of flashes. The fault light will illuminate for 0.25 
seconds (250mS), then turn off for 0.25 seconds (250mS), followed by a 2 second off interval. The 
number of flashes between each 2 second off period is used to indicate the different fault conditions. 
Table 37.
Power-On Fault Codes
The fault code should be noted (along with the drive serial number if possible), and either the supplier 
of the SSD unit or technical support should be contacted.
Flash Series
Condition
1 Flash
Memory strobe adjustment failure.
2 Flashes
Memory address failure.
3 Flashes
Memory data failure.
4 Flashes
ECC error encountered during memory test.
5 Flashes
ECC detection/correction circuit failure.