Whenever the unit will not be used for 
30 days or longer, use the following 
procedures to prepare if for storage:

Clean external parts thoroughly.

Drain all the fuel from the carbure-
tor and the fuel tank.
IMPORTANT!
All stored fuels should be stabilized 
with a fuel stabilizer such as StaBil™.
To remove the remaining fuel from the 
fuel lines and carburetor and with the 
fuel drained from the fuel tank… 
1.  Prime the primer bulb until no more 
fuel passes through.
2.  Start the engine and idle until it 
stops running.
3.  Repeat Steps 1 and 2 until the en-
gine will no longer start.
CAUTION!
Gasoline stored in the carburetor 
for extended periods can cause 
hard starting and could also lead to 
increased service and maintenance 
costs.
Long Term Storage

Remove the spark plug and put a 
small amount of 2-cycle mixing oil 
(1-2 cm
3
) into the cylinder through 
the spark plug hole. Slowly pull 
the recoil starter 2 or 3 times so oil 
will evenly coat the interior of the 
engine. Reinstall the spark plug.

Before storing the unit, repair or 
replace any worn or damaged parts.

Remove the air cleaner element 
from the carburetor and clean it as 
described on page 17, then reas-
semble the element.

Clean the exterior of the unit thor-
oughly.

Store the unit is a clean, dust-free 
area.