Siemens Network Hardware D410 用户手册
ESD guidelines
B.3 Basic measures for protection against discharge of static electricity
D410
144
Commissioning Manual, 08/2008 Edition
This figure indicates the maximum electrostatic charges that can accumulate on an operator
when he comes into contact with the indicated materials. These values comply with the
specifications in IEC 801-2.
9ROWDJHLQN9
N9
5HODWLYHKXPLGLW\LQ
6\QWKHWLFPDWHULDO
:RRO
$QWLVWDWLFPDWHULDOHJZRRGRUFRQFUHWH
Figure B-2
Electrostatic voltage that can accumulate on operating personnel
B.3 Basic measures for protection against discharge of static electricity
Ensure sufficient grounding
When working with electrostatic sensitive devices, make sure that the you, your workstation,
and the packaging are properly grounded. This prevents the accumulation of static
electricity.
Avoid direct contact
You should only touch ESD components if unavoidable (for example, during maintenance
work). When you touch modules, make sure that you do not touch either the pins on the
modules or the printed conductors. If you follow these instructions, electrostatic discharge
cannot reach or damage sensitive components.
If you have to take measurements on a module, make sure that you first discharge any static
If you have to take measurements on a module, make sure that you first discharge any static
that may have accumulated in your body. To do this, touch a grounded metal object. Only
use grounded measuring instruments.