AT Command Set
MC35_ATC_01_V04.00
Page 65 of 238
02.04.2002
4.7  AT+CCLK  Real Time Clock
Test command
AT+CCLK=?
Response
OK
Read command
AT+CCLK?
Response
+CCLK: <time>
OK/ERROR/+CME ERROR
Parameter:
<time>:  string type value; format is "yy/MM/dd,hh:mm:ss", where characters
indicate year (two last digits), month, day, hour, minutes, seconds;
e.g. 6
th
 of May 2001, 22:10:00 hours equals to “01/05/06,22:10:00"
Write command
AT+CCLK=<time>
Response
OK/ERROR/+CME ERROR
Parameter:
<time>
see read command
Reference
GSM 07.07
Note
•  <time> is retained if the device enters the Power Down mode via
AT^SMSO (pg. 192).
•  <time> is lost if power is totally disconnected and if no separate battery
back-up for the clock is provided via the ZIF cable. In this case, the clock
starts with <time> = “00/01/01,00:00:00” upon next power-up.
•  See AT+CALA, pg. 56.
•  When the GSM engine wakes up to Alarm mode, the system takes 1s to
re-initialize the RTC and to update the current time. Therefore, it is rec-
ommended to wait 1s before using the AT+CCLK command (for example
1s after ^SSYSTART has been output).