CO-100 Offl ine Lock User Guide
 RESETTING TO FACTORY DEFAULTS
All information in the lock will be deleted and reset to factory defaults!
In the factory default reset state, offl ine locks have a default PIN of 13579 and “#”, which can be used 
for installation and testing.
Follow these steps to reset to factory defaults.
1. Remove the top inside cover.
2. Remove one battery from the battery pack to disrupt power. Wait 5 to 10 seconds for power to run 
out in the lock.
3. Press and hold the Schlage button while reconnecting the battery 
into the battery pack to resupply power.
4. Continue holding the Schlage button, and wait for two beeps to 
sound and two green blinks of the Schlage button.
5. Release the Schlage button.
6. Press and release the Schlage button three (3) times within 10 
seconds of the beeps and blinks at step 4. One beep will sound and 
one red blink will occur with each press.
7. The Schlage button will light green for one second and a one-second 
beep will sound, indicating that the lock has been reset.
 
If the Schlage button is not pressed 3 times within 10 seconds,
two beeps and two red blinks indicate timeout.
8. Replace the top inside cover.
To test, enter 13579 and “#”. The Schlage button will blink and the lock will unlock.
TIP
If the Schlage button is 
not pressed and held 
while reconnecting the 
battery, then the lock 
is ready for normal 
operation (as after a 
power-on reset).