ATV58 TRX TYPE E DRIVE CONTROLLERS
The ATV58 TRX family of adjustable-frequency AC drive controllers is used 
to control three-phase asynchronous motors. The ATV58 TRX Type E model 
contains an ATV58 TRX Type H drive controller packaged in a compact, Type 
1 enclosure. It is for use in mechanical rooms, OEM equipment, and factory 
floor applications. The following Type E drive controller models are available:
• 1 to 7½ hp (0.75 to 5.5 kW), 400/460 Vac, three-phase input
• ½ to 3 hp (0.37 to 2.2 kW), 200/240 Vac, single-phase input
• 2 to 3 hp (1.5 to 2.2 kW), 200/240 Vac, three-phase input
Each ATV58 TRX Type E drive controller contains:
• A GV2 manual motor starter, ATV58 TRX drive controller, and an output 
contactor
• A three-position selector switch wired for “RUN FORWARD”
• A manual speed potentiometer mounted on the front of the enclosure
• Space for two additional 16-mm operators
• Four conduit openings that are closed with plugs
• A transparent plastic door for viewing the status LEDs and a separately-
supplied keypad
All ATV58 TRX communication and I/O options can be used in the Type E 
controllers. The Type E drive controllers can be used on constant or variable 
torque applications. The ratings are shown in the tables below.
200 Vac -10% / 240 Vac +10% at 50/60 Hz ±5%, Single-Phase Input with 3-Phase Output
Frame 
Size
Drive Controller 
Catalog Number 
Motor Power
Rated 
Output Current
Transient 
Output Current
kW
HP
A
A
1
ATV58EU09M2ZU
0.37
0.5
2.3
3.1
1
ATV58EU18M2ZU
0.75
1
4.1
5.6
2
ATV58EU29M2ZU
1.5
2
7.8
10.6
3
ATV58EU41M2ZU
2.2
3
11
15
200 Vac -10% / 240 Vac +10% at 50/60 Hz ±5%, 3-Phase Input with 3-Phase Output
Frame 
Size
Drive Controller 
Catalog Number 
Motor Power
Rated 
Output Current
Transient 
Output Current
kW
HP
A
A
2
ATV58EU29M2ZU
1.5
2
7.8
10.6
3
ATV58EU41M2ZU
2.2
3
11
15
400 Vac -10% / 460 Vac +10% at 50/60 Hz ±5%, 3-Phase Input with 3-Phase Output
Frame 
Size
Drive Controller 
Catalog Number 
Motor Power
Rated 
Output Current
Transient 
Output Current
kW
HP
A
A
2
ATV58EU18N4ZU
0.75
1
2.3
3.1
2
ATV58EU29N4ZU
1.5
2
4.1
5.6
2
ATV58EU41N4ZU
2.2
3
5.8
7.9
3
ATV58EU54N4ZU
3
7.8
10.6
3
ATV58EU72N4ZU
4
5
10.5
14.3
3
ATV58EU90N4ZU
5.5
7.5
13
17.7
For dimensions, see page 122; for wiring diagrams, see pages 109 and 110.
Power indicated is for a switching frequency between 0.5 and 4 kHz, and at steady state. For switching 
frequency between 8 and 16 kHz, use the next largest size drive controller. (For example, for 2 hp, order drive 
controller ATV58EU41M2ZU.) If the duty cycle (that is, the drive controller run time) does not exceed 60% (36 
second maximum for a 60 second cycle), this is not necessary.
For 60 seconds.
A line reactor (3% minimum) must be used with this drive controller.