Notes to Observe in Using the REAC System
 
The REAC cables used in digital snake systems employ computer network technology to 
enable transmission of multichannel audio signals.
In very rare cases, however, noise may be generated when these systems are used in 
certain environments. If noise is present, check the following points.
 
 
Ensure that cables used for REAC connections conform to the Cat5e (Ethernet Category 5) 
standard.
 
 
No single cable should be longer than 100 meters.
 
 
Do not use cables with cut or torn coverings.
 
 
Do not subject cables to undue stress.
 
 
Do not wind or bend cables such that the radius of the turn is 25 mm or less, and do not double 
cables over.
 
 
Do not bind cables tightly into bundles.
 
Concerning REAC Cables and Their Handling
To maintain the transmission 
quality of REAC digital 
communication, use the 
following optional items as 100-
meter and 20-meter REAC cables.
100-meter REAC cables
• SC-W100S
• W100S-R
20-meter REAC cables
• SC-W20F
S-4000D_e.book 12 ページ 2010年10月8日 金曜日 午後1時1分