Serial (RS-232) Controls and Operation
142
AX3500 Motor Controller User’s Manual
 Version 1.9b. June 1, 2007
RS-232 Watchdog
For applications demanding the highest operating safety, the controller may be configured 
to automatically stop the motors (but otherwise remain fully active) if it fails to receive a 
character on its RS232 port for more than 1 seconds. 
The controller will also send a “W” character every second to indicate to the microcom-
puter that such a time-out condition has occurred.
The character does not need to be a specific command, but any ASCII code, including invis-
ible ones.
The RS232 watchdog is enabled or disabled depending on the value of the “Input Com-
mand Mode” parameter.
The RS232 watchdog is automatically enabled when entering the RS232 mode from the 
RC or from the Analog modes (see “Entering RS232 from R/C or Analog mode” on 
page 140)
Controller Commands and Queries
AX3500 commands and queries are composed of a series of 2 or 4 characters followed by 
the “enter” (carriage return) code.
The controller will send back (echo) every character it is receiving. By checking that the 
returned character is the same as the one sent, it is possible to verify that there has been 
no error in communication.
After a command has been received and properly executed, the controller will send the 
“+” character.
If a command has been received with errors or bad parameters, the controller will send the 
“-” character.
The table below lists the AX3500 RS232 commands and queries
TABLE 24. Controller’s basic Commands and Queries
Command
Type
Description
%rrrrrr
Command
Reset Controller
!Ann
Command
Channel 1, forward command to value nn
!ann
Command
Channel 1, reverse command to value nn
!Bnn
Command
Channel 2, forward command to value nn
!bnn
Command
Channel 2, reverse command to value nn
!C
Command
Turn Accessory Output C n
!c
Command
Turn Accessory Output C Off
?a or ?A
Query
Read Battery Amps
?v or ?V
Query
Read Power Level applied to motors
?p or ?P
Query
Read Analog Inputs 1 and 2
?r or ?R
Query
Read Analog Inputs 3 and 4