RoboteQ Dual Channel High Power Digital Motor Controller AX3500 用户手册

下载
页码 208
AX3500 Motor Controller User’s Manual
37
Wire Length Limits
Wire Length Limits
The AX3500 regulates the output power by switching the power to the motors On and Off 
at high frequencies. At such frequencies, the wires’ inductance produces undesirable 
effects such as parasitic RF emissions, ringing and overvoltage peaks. The controller has 
built-in capacitors and voltage limiters that will reduce these effects. However, should the 
wire inductance be increased, for example by extending the wire length, these effects will 
be amplified beyond the controller’s capability to correct them. This is particularly the case 
for the main battery power wires.
Important Warning
Avoid using long cable lengths (beyond 2 feet) from the main power battery to the 
controller as the added inductance may cause damage to the controller when oper-
ating at high currents. Try extending the motor wires instead since the added induc-
tance is less harmful on this side of the controller.
If the controller must be located at a longer distance, the effects of the wire inductance 
may be reduced by using one or more of the following techniques:
Twisting the power and ground wires over the full length of the wires
Use the vehicle’s metallic chassis for ground and run the positive wire along the sur-
face
Add a capacitor (5,000uF or higher) near the controller
Electrical Noise Reduction Techniques
As discussed in the above section, the AX3500 uses fast switching technology to control 
the amount of power applied to the motors. While the controller incorporates several cir-
cuits to keep electrical noise to a minimum, additional techniques can be used to keep the 
noise low when installing the AX3500 in an application. Below is a list of techniques you 
can try to keep noise emission low:
Keep wires as short as possible
Loop wires through ferrite cores
Add snubber R/C circuit at motor terminals
Keep controller, wires and battery enclosed in metallic body
Power Regeneration Considerations
When a motor is spinning faster than it would normally at the applied voltage, such as 
when moving downhill or decelerating, the motor acts like a generator. In such cases, the 
current will flow in the opposite direction, back to the power source.
It is therefore essential that the AX3500 be connected to rechargeable batteries. If a power 
supply is used instead, the current will attempt to flow back in the power supply during 
regeneration, potentially damaging it and/or the controller.
Regeneration can also cause potential problems if the battery is disconnected while the 
motors are still spinning. In such a case, and depending on the command level applied at