RoboteQ Dual Channel High Power Digital Motor Controller AX3500 用户手册

下载
页码 208
AX3500 Motor Controller User’s Manual
83
Wiring Limit Switches Without Encoders
When the switch is activated, the module’s input is pulled to 0V.
It is recommended that a voltmeter and/or oscilloscope be used to verify that the right volt-
age levels are created as the encoder rotates and the switches activate. 
You may also use the Encoder setup/test function in the Roborun utility (see “Encoder 
Testing and Setting Using the PC Utility” on page 87
). If the wiring is correct, the counters 
should increment/decrement as the motor rotate. The switch indicators should be always 
off unless the switches are actually activated.
Wiring Limit Switches Without Encoders
If no encoder is used, the Encoder Module’s inputs can be used to wire limit switches 
directly with solely a pull-up resistor as shown in the diagram below.
Effect of Limit Switches
Each pair of limit switches will stop the motion of a given motor in a given direction. This 
will have the effect of stopping the motor when a limit is reached while allowing motion in 
the other direction, away for that limit.
TABLE 15. Effects of Limit Switches 1 and 2 on Motor 1
SW1
SW2
Motor 1 Fwd
Motor 1 Rev
OFF
OFF
Allowed
Allowed
ON
OFF
Stopped
Allowed
OFF
ON
Allowed
Stopped
ON
ON
Stopped
Stopped
SW3
SW4
Encoder Input
GND
5V Out
Ch B In
Ch B In
Ch A In
6
1
2
5
8 - 4
7 - 3
Ch A In
4.7kOhm
4.7kOhm
SW1
SW2
4.7kOhm
4.7kOhm
FIGURE 54. Signals seen by encoder using multi-levels and limit switches