AX500 Motor Controller User’s Manual
109
Controller Commands and Queries
!C
turn C output off
!c
turn C output on
Query Power Applied to Motors
Description:
This query will cause the controller to return the actual amount of power that is being 
applied to the motors at that time. The number is a hexadecimal number ranging from 0 to 
+127 (0 to 7F in Hexadecimal). In most cases, this value is directly related to the command 
value, except in the conditions described in the notes below.
Syntax:
?v or ?V
Reply:
nn
mm
Where:
nn = motor 1 applied power value
mm = motor 2 applied power value
Notes:
The applied power value that is read back from the controller can be different than the com-
mand values for any of the following reasons: current limitation is active, motors operate at 
reduced speed after overheat detection, or mixed mode is currently active.
No forward or reverse direction information is returned by this query. This query is most 
useful for providing feedback to a microcontroller commanding the controller.
Query Amps from Battery to each Motor Channel
Description:
This query will cause the controller to return the actual number of Amps flowing from the 
battery to power each motor. The number is an unsigned Hexadecimal number ranging 
from 0 to 256 (0 to FF in Hexadecimal). 
Syntax:
?a or ?A
Reply:
nn
mm
Where:
nn = motor 1 Amps
mm = motor 2 Amps
Notes:
The Amps measurement has an approximately 10% precision. Its main purpose is to pro-
vide feedback to the controller’s current limitation circuitry.
Important Notice
The current flowing in the motor can be higher than the battery flowing out of the battery. 
See “Battery Current vs. Motor Current” on page 39.