RoboteQ Dual Channel Digital Motor Controller AX500 用户手册

下载
页码 154
AX500 Motor Controller User’s Manual
113
Accessing & Changing Configuration Parameter in Flash
Syntax:
^FF
Reply:
+ Success, changed parameters are now active
- if error
Table 18 below lists the complete set of configuration parameters that may be accessed 
and changed using RS232 commands. 
Flash Configuration Parameters List
TABLE 18. Configuration parameters in Flash
Location
Description Active 
after
^00
Input control mode
Reset
^01
Motor Control mode and Closed Loop Feedback type
Reset or ^FF
^02
Amps limit
Reset or ^FF
^03
Acceleration
Reset or ^FF
^04
Input Switch function
Reset or ^FF
^05
reserved
^06
Joystick Deadband or Analog Deadband
Reset or ^FF
^07
Exponentiation on channel 1
Instant
^08
Exponentiation on channel 2
Instant
^09
Reserved
^0A
Left / Right Adjust
Reset or ^FF
^0B
Reserved
Reset or ^FF
^0C
Reserved
Reset or ^FF
^0D
Reserved
^0E
Reserved
Reset or ^FF
^0F
Gain Integral for PID
Reset or ^FF
^10
Gain Diff for PID
Reset or ^FF
^11
Gain Prop for PID
Reset or ^FF
^12
Joystick Center 1 MS
Instant
^13
Joystick Center 1 LS
Instant
^14
Joystick Center 2 MS
Instant
^15
Joystick Center 2 LS
Instant
^16
Joystick Min 1 MS
Instant
^17
Joystick Min 1 LS
Instant
^18
Joystick Min 2 MS
Instant
^19
Joystick Min 2 LS
Instant
^1A
Joystick Max 1 MS
Instant