Connecting Power and Motors to the Controller
26
AX500 Motor Controller User’s Manual
 Version 1.9b. June 1, 2007
Controller Power
The AX500 uses a flexible power supply scheme that is best described in Figure 8. In this 
diagram, it can be seen that the power for the Controller’s processor is separate from this 
of the motor drivers. In typical applications, the VMot is connected in permanence to the 
battery while VCon is connected to the battery through a On/Off switch.
VMot
Motor 2
Motor 1
M2+
M1-
M1+ VMot
M2-
3 x Gnd
VCon
FIGURE 7. AX500 Controller Rear View
Note:
Both VMot terminals are 
connected to each other in 
the board and must be 
wired to the same voltage.
Channel 1 MOSFET Power Stage
Channel 2 MOSFET Power Stage
5Vmin
30V max
Microcomputer & 
MOSFET Drivers
8V min
30V max
5Vmin
30V max
Vcon
Vmot
M1-
M2-
M1+
M2+
Vmot
GND
GND
GND
FIGURE 8. Representation of the AX500’s Internal Power Circuits