TE C H N I C A L   S P E C I F I C A T I O N S
Parameter Storage
350-7951
Quadra User’s Guide
124
. .
 . 
.
Configuration values
 — The following configuration values are 
stored:
~
X and Y repeat rates used in interactive image position and 
pan
~
Scale step used in interactive image size and zoom
Serial port settings
 — The following settings are stored for RS-232 
control port:
~
Baud rate
~
Echo
~
Handshaking
. . . . . . . . . 
TIMING PRESETS
In addition to the factory supplied timing presets, users are allowed to save and 
recall up to 61 timing presets.  Note that Quadra has a common timing list that 
can be applied to either input or output ports.
There are three ways to create a timing preset entry.  The first two are listed 
immediately below.  Note that they store a limited number of timing parameters 
as listed in the “Timing Preset” list below. 
Output timing
 — Timing presets may be created by saving output 
timing settings using th
 command. 
Direct loading
 — Timing presets may be created by directly loading 
them using th
Timing presets contain the following parameters:
Timing preset name
Horizontal front porch, sync width, back porch, and active area (in 
pixels)
Vertical front porch, sync height, back porch, and active area (in lines)
Horizontal and vertical frequencies
Sync format
Horizontal and vertical sync polarities
Interlace
Timing presets that were created by saving input timing with th
 
command will contain all of the above settings — in addition to the following 
supplemental parameters:
ADC sample phase
De-interlacer mode
ADC gain and offset values for Red, Green, and Blue channels
Brightness, Contrast, Hue, Saturation, Filter settings, Aspect Ratio and 
Over/Underscan mode