RF-Link Technology NL6000 用户手册

下载
页码 50
RF Neulink
NL6000 User Guide
25
5.6.5. Carrier Sense Multiple Access
If a unit s transmit and receive frequencies are the same, it may be helpful  to
enable Carrier Sense Multiple Access (CSMA). This option does not  allow
transmission of a packet until the channel is free of contention.
5.7.
Serial Connection to an I/O Device
5.7.1. Basic Serial Parameters
The NL6000 can receive data strings from a variety of I/O devices through  its
RS232 serial port. Configure the NL6000 serial port parameters based upon
how the I/O device will send data to the unit. The following is a list of the basic
serial parameters you must configure:
Baud rate
This parameter is the data rate between the I/O device and
the NL6000 modem. Set the baud rate to the rate of the I/O device.
Data bits
This parameter is the number of bits the I/O device sends in a
byte. The options available are 7 or 8. The NL6000 does not use  parity
bits.
Stop bits
This parameter is the number of bits used for the end of a
byte. The options available are 1 or 2.
Transmit Character Timeout
The NL6000 transmits a data packet on
the radio channel when there is a timeout on the serial port equal to this
value or when the amount of data in the input buffer is equal to the
Maximum Packet Size.
5.7.2. Flow Control
Prior to configuration of the NL6000, determine if you want to use flow control
to prevent the serial device or modem from overflowing its buffer. If flow
control is desired, two types are available
RTS/CTS and  XON/XOFF. With
RTS/CTS, the modem monitors the RTS signal to  determine when to send
data to the serial device. In addition, the modem  asserts CTS when the
modem is ready to accept data from the serial  device. RTS/CTS is the
preferred method of flow control, but it requires  separate lines for RTS and
CTS. If you cannot use hardware flow control, you may use the XON/XOFF
software option for flow control. This option  may only be used for ASCII data
and requires the use of special characters  to identify when it is OK to send/
receive data to/from the serial device.
5.7.3. DCD Mode
The DCD Mode parameter identifies how the I/O device interprets the  current
state of the modem using the DCD line between the device and the  modem. If
the mode is set to Enable, the modem asserts the DCD line  when it is
receiving data over-the-air. If the mode is set to Disable, the  modem asserts
the line when it is in a normal operating state and negates  the line when it is in