Rangemaster 110 DUAL FUEL U109600-02 用户手册

下载
页码 40
33
SERVICING  - WARNING 
Disconnect  from  electricity  and  gas  before  servicing.  Check  appliance  is  safe  when  you  have  finished.
Conversion to LP gas
Check in the Technical Data section at the back of the 
book that the cooker is convertible to the gas you want 
to use.
This conversion must be performed by a competent 
person. After conversion the installation must 
comply with the relevant regulations and also the 
local electricity supply company requirements. 
Read the instructions before converting this 
appliance. 
Failure to convert the appliance correctly could 
invalidate any warranty or liability claims and lead 
to prosecution.
This instruction must be used in conjunction with the rest 
of the appliance instruction, in particular for information on 
Standards, cooker positioning, connection hose suitability 
etc.
When servicing or replacing gas-carrying components 
disconnect from gas before commencing operation and 
check appliance is gas sound after completion.
Do not use re-conditioned or unauthorised gas controls.
Jets
           Standard burner                                                   Wok burner
A jet, B internal injector, C external injector
Remove burner caps and heads. Remove old jets. Fit new 
jets (see Technical Data section at the back of the book for 
correct jets). Reassemble in reverse order. 
Tap adjustment 
Pull off all the control knobs. If the hand rail has been fitted 
remove it - remove the plastic blanking plugs and remove 
the 2 end bracket fixing screws.
Remove the 2 cross headed screws that were hidden by the 
hand rail end brackets.
Open the oven door & or grill door and remove the fixing 
screws underneath the control panel. NB some models have 
a plate under the facia held in place by the bottom fixing 
screws.
Lower facia panel clear of top retaining tags.
A  tap bypass screw
Turn the bypass screw on each gas control clockwise to the 
stop.
Stick on label
Stick the appropriate label on to the data badge to indicate 
the gas the appliance is now set for.
Pressure Testing
Connect the appliance to the gas supply. Check the 
appliance is gas sound.
The gas pressure can be measured at one of the left hand 
hotplate burner jets. Lift off a burner head. Fit the pressure 
gauge to the jet. Turn on the hotplate burner and turn on 
and light one of the other burners.
Reassemble burner top, making sure it is reassembled in the 
correct way on the burner body.
Check the appliance is gas sound.
Check operation of all the burners.