I
NSTALLATION
V
ORTEX
 EF2241
 
Reference Manual
8
Technical Support: 800.932.2774
I
NSTALLATION
This equipment is intended to only be installed by qualified service personnel.  The 
equipment shall be connected to a socket-outlet that provides a protective earthing 
connection.
North American 
Requirement
CAUTION-To reduce the risk of fire, use only No. 26 AWG or larger telecommunica-
tion line cord.
M
OUNTING
 
THE
 EF2241
The EF2241 can be mounted in a rack enclosure using four large screws (10-32x1/2”) 
included with the unit. One EF2241 fits in a single rack space.
Recommendation 
For Easy Access
While not required, leave a single rack space in between the EF2241 and other units 
in your rack.  This gives you easier access to the back panel.
Instructions for 
Securing Power 
Supply to Back of 
EF2241
Locate the cable clamp on the back panel of the EF2241 above the power con-
nector.
Remove the screw and thread the power cord through the cable clamp.
Attach the cable clamp to the back panel of the EF2241 and tighten the screw.  
Align the clamp so that the power cable does not interfere with the connectors on 
the EF2241 back panel.
Plug in the power supply.
We recommend that you also Ty-wrap the power supply to the rack.  The purpose 
of securing the power supply to the back panel is so that if the power supply were 
to drop, it would pull where the cord is attached with the cable clamp and not pull 
the plug out of the EF2241.
C
ONNECTING
 
THE
 EF2241 
TO
 O
THER
 E
QUIPMENT
Grounding
The EF2241 has 4 mic/line inputs plus 4 line level inputs and 8 line level outputs.  
Each input/output is “Pin 1 compatible” — this means that the ground pin of each 
input/output is tied to chassis ground.  Chassis ground is connected to the input power 
ground.
Caution! 
Do not use any other power supply other than the one pro-
vided with this unit.