Global Settings. 
Decay Time. Decay time is the amount of time the microphone audio takes to 
ramp down to the Off Attenuation level after Hold Time.  Decay Time values 
range from 0 to 5000 msec.  The default value is 1000 msec.
Hold Time. This is the amount of time the microphone stays On after the energy 
in the channel drops below the gating threshold.  The default value is 500 msec.  
The range is 1 to 5000 msec.  Microphone channels gating On and Off too fre-
quently during short pauses in speech might be the result of setting the Hold 
Time too low while too many microphones gating on at the same time may be the 
result of Hold Time values that are too high.
Camera Gating Threshold. Specifies the hold time for camera gating informa-
tion.
Figure 22. Automixer parameters.
Ambient Level
A
DAPTIVE
 T
HRESHOLD
Channel OFF
Channel ON
Channel turns on when 
signal level is above 
Adaptive Threshold
Microphone 
Audio
Time
Signal Level
H
OLD
 
T
IME
O
FF
 A
TTENUATION
D
ECAY
 
T
IME
Global Settings
Decay
Hold Time
Camera Gating
Threshold
Automixer