 Insert the tube with the rubber ring in the
UV chamber.
D
Note:
Make sure you put the rubber ring and
quartz tube in the correct position.
9
 To reattach the UV lamp unit, follow steps 6
to 8 in section ‘Replacing the UV lamp unit’.
10
 Close the cover of the UV chamber.
7.0.4 Replacing the filter
D
Note:
Switch off the pure water dispenser before you
replace the filter.
The filter has a capacity of up to 3000 litres. 
When 00 litres have passed through the 
filter, the filter indicator c starts flashing to indicate 
that you need to replace the filter. At this point, 
the appliance can still dispense another 300 litres 
of water, giving you time to arrange a new filter. 
The filter indicator keeps flashing until 3000 litres 
have passed through the filter. Then the filter 
indicator lights up red continuously and the pure 
water dispenser does not dispense water until you 
replace the filter. 
D
Note:
We advise you to change the filter every
6 months, even though you might not have
consumed 3000 litres. Filter life is subject to the
actual level of impurities in your water supply.
The filter may therefore expire before 3000
litres without any warning period. 
1
 Switch off the pure water dispenser.
7.0.3 Cleaning the quartz tube
We advise you to clean the quartz tube once 
every  months.
B
Warning:
Handle the quartz tube with care, as it might
break and cause injury. Do not tamper with the
quartz tube (apply glue, etc.).
1
 Switch off the pure water dispenser.
2
 Open the cover of the UV chamber.
3
 To remove the UV lamp unit, follow steps 1
to 5 in section ‘Replacing the UV lamp unit’.
4
 Pull out the quartz tube with the rubber
ring.
5
 Remove the rubber ring.
6
 Clean the quartz tube with a clean moist
cloth and dry it completely.
7
 Reinsert the rubber ring to a depth of 2-
3mm from the open end.