Paradyne Broadband Access Concentrator 8820 用户手册

下载
页码 108
1. Network Management Specification
66
 
 June 2003
8000-A2-GB30-00
7.1.2.1.15
entPhysicalAssetID
This object is a user-assigned asset tracking identifier for the physical entity as specified by 
a network manager, and provides non-volatile storage of this information. If no asset 
tracking information is associated with the physical component, then this object will contain 
a zero-length string.
Valid Object Value(s):
The following table shows the entPhysicalAssetID assigned by default to the entities. NMS 
systems can modify these default values for some entities as indicated below.
7.1.2.1.16
entPhysicalIsFRU
This object indicates whether or not this physical entity is considered a ’field replaceable 
unit’ by the vendor.  If this object contains the value ’true(1)’ then this entPhysicalEntry 
identifies a field replaceable unit.  For all entPhysicalEntries which represent components 
that are permanently contained within a field replaceable unit, the value ’false(2)’ should be 
returned for this object.
Valid Object Value(s):
The following table shows the entPhysicalIsFRU designated for the entities.
Table 1-74. entPhysicalAssetID
Entity
entPhysicalAssetID
Chassis
zero-length-string (read-write)
Container
zero-length-string (read-write)
Module
zero-length-string (read-write)
Splitter card
zero-length-string (read-write)
DSL Port
zero-length-string (read-only)
T1/E1 port
zero-length-string (read-only)
OC3 port
zero-length-string (read-only)
Console port
zero-length-string (read-only)
Ethernet Mgmt port
zero-length-string (read-only)
Temp Sensor
zero-length-string (read-only)
Fan
zero-length-string (read-only)
PowerSupply
zero-length-string (read-only)
Management Plane PLD
zero-length-string (read-only)
Table 1-75. entPhysicalIsFRU (1 of 2)
Entity
entPhysicalIsFRU
Chassis
TRUE
Container
TRUE
Module
TRUE