1. Network Management Specification
70
 
 June 2003
8000-A2-GB30-00
7.2.2
mpeEntPhysicalExtOperStatus
This is a read-only object that allows managers to determine the operational status of the 
entities in the managed device. The possibles values are ’up’, ’down’ and ’testing’.
7.3
Entity Sensor MIB (RFC 3433):
This MIB has only one group (entitySensorValueGroup) which consists of a single 
(read-only) table that will be supported as indicated in the following table. There will be as 
many entries as sensors. For the GranDSLAM 3.0 product, there will be three temperature 
sensors 
7.3.1
entPhySensorType.
The value for this object corresponds to the measurement data type. The value of this object 
will be celsius (8). 
7.3.2
entPhySensorValue.
The value corresponds the most recent measurement obtained by the agent for this sensor.
7.3.3
entPhySensorOperStatus.
The operational status of the sensor. The following status will be reported: ok (1), 
unavailable (2), nonoperational (3).
7.3.4
entPhySensorValueTimeStamp.
The value of this object corresponds to the sysUpTime at the time the status and/or value fo 
this sensor was last obtained by the agent.
7.3.5
entPhySensorValueUpdateRate.
The value of this object is an indication of the frequency that the agent updates the 
associated entPhySensorValue object. The value to be returned will be zero. This value has 
a special meaning in the mib.
7.4
Definitions for the IEEE 802.3 Medium Attachment Units (MAUs) (RFC 2668):
RFC 2668 is used for accessing information about of ethernet interface. The following 
objects are supported.
7.4.1
ifMauTable:
Table of descriptive and status information about MAU(s) attached to an interface. The 
following objects in this table are supported.
Table 1-81. Entity Sensor MIB
Table
Comments
entPhySensorEntry
Only the objects listed below will be supported