Trac Door model 988 & 988WL 用户手册

下载
页码 8
©2005 TRAC-RITE DOOR, INC.
Prior to beginning door installation, read the instruction
manual in its entirety.  Please contact Trac-Rite with any
questions at 888-700-8722.  Answering questions up front will
greatly reduce the probability of installation miscues.
1.  GENERAL:
In this document, the following terms are defined as:
Warning -  serious personal injury or death can result from
failure to follow instructions.
Caution -  minor injury or property damage can result from
failure to follow instructions.
Note  -          special attention should be given to the instructions.
- Do not cut the bands which hold the door curtain in
a roll!
  This is performed once the door has been hung in
the opening.
- Once the door has been installed, you will find full door
height strips of white felt tape on the inside of the door
curtain.  Do not remove!  It is not packaging material.
2.  INSPECTION:
2.1  Door and Hardware:  Upon receiving the door shipment,
immediately inspect the door and hardware for damage.
Verify the product received with the packing list.  Damages
and/or shortages should be reported immediately to Trac-Rite
customer service at 800-448-8979.  Please have your bill of
Do not install this rolling steel curtain door unless
you read and understand the installation
instructions!
NOTE!
WARNING
Improper installation of anchoring devices or installation into aged or unsound concrete
block or other wall material may result in premature product wear, product failure,
property damage or serious personal injury.
Page 3
RECOMMENDED INSTALLATION CLEARANCES
OPENING HEIGHT
7' - 10" - 16' - 0" WL
A
21"
B
23"
WOOD/
STEEL
C
7.5"
7.5"
*
*
*  ADD 1" TO A AND B FOR INSULATED DOORS.
MASONRY
C
9"
9"
OPERATOR
MOTOR
C
21.5"
21.5"
**  IF CHAIN HOIST IS NOT PURCHASED, AXLE CAN BE CUT
OFF FOR EXTRA SIDE CLEARANCE
7' -10 " - 16' - 0"
20"
22"
Figure 1.
Do not use model 944 and 955 hardware on model
988 doors.  It is not structurally adequate.  If door
falls, serious injury and/or damage to door can
result.
WARNING
lading and packing list to reference when reporting shortages
or damage.  Do not install damaged material without
authorization from Trac-Rite.
2.2  Door Width Verification:  The door curtain width should
measure 5” greater than the framed opening width. If the door
is equipped with windlocks, the curtain width should measure
3” greater than the framed opening.
2.3  Framed Opening Verification:
Proper size dimensionally?
Opening square?  Plumb?
Is the jamb structurally/dimensionally adequate?
Reference paragraph 3. Jamb Preparation for specifics.
Clearances?  (Reference Figure 1)
3.  JAMB PREPARATION:
3.1  Are the jambs structurally and/or dimensionally adequate
to accept door brackets and guides?  Trac-Rite is not
responsible for the structural integrity of the jamb itself!
3.2   Trac-Rite does not supply fasteners for attaching the
door brackets and guides to concrete or concrete masonry
jambs.  Trac-Rite does supply fasteners for metal and wood
jambs.
Door bracket to jamb fasteners must be 3/8” in