Texas Instruments TRF1500 用户手册

下载
页码 74
SWRA004A
40
TRF1500 Integrated Dual-Band RF Receiver User’s Guide
High-Band Cascaded Test Guide
This section involves measuring the cascaded performance of the
High Band LNA, High Band Mixer and High Band IF Amp using
the Frequency Doubler.  All tests apply for an IF output terminated
into a 1 k
Ω
 differential load. A transformer balun is used to match
the IF output to the 50 
Ω
 test equipment.  All unused ports are
terminated into 50 
Ω
.
Table 4.  HB LNA, HB mixer, HB IF amp
PARAMETERS
 Min
Typ
Max
 UNIT
RF Input Frequency Range
1930
1960
1990
MHz
Direct Drive LO Frequency Range
2040.52
2070.52
2100.52
MHz
Doubler Drive LO Frequency Range
1020.26
1035.26
1050.26
MHz
IF Frequency
110.52
MHz
RF Input Power
-30
dBm
LO Input Power
-5
dBm
Power Conversion Gain
26.3
dB
Power Conversion Gain Reduction
43.5
dB
Image Rejection
22.5
dB
Noise Figure
4.66
dB
RF Input Return Loss
14.2
dB
LO Buffer Output Power
-14
dBm
Power Leakage LO In to RF In
-50
dBm
Third Order Input Intercept Point(IIP3)
-17.7
dBm
1dB RF Input Compression Point
-23.7
dBm
2X2 Spur Performance
69
dBc
3X3 Spur Performance
81
dBc
High-Band Cascaded: Power Conversion Gain
Control state: 111001
SEE APPENDIX A: TEST BENCH SETUPS
Test setup Figure 20
The high band power conversion gain (dB) is the measured power
(dBm) at the IF frequency minus the RF source power (dBm). It is
measured using a RF source and a spectrum analyzer.
1)  Set the RF source power (RF P
in
) and the desired frequency
(see Table 4). Connect the RF source to the EVM RF port,
J20.