T1 Remote Module Installation 
 
Link WTS – Link 3000 MCU 
4.  Install System at Remote Site 
4.1 Survey 
Site 
Check the site to be sure pre-installation work has been completed correctly.  This 
includes: 
•  Location chosen for the shelves is adequate. 
•  Rack (if rack mounted) is properly secured or backboard (if wall mounted) is properly 
prepared. 
•  Power is available. 
•  Wiring to Base Station locations has been pulled and correctly terminated. 
•  Phone lines for the Wireless Telephones are installed and properly terminated. 
•  Telephone system administrator is available to program the existing telephone 
system. 
4.2 Install 
Shelves 
Rack Mount 
To install shelves in the rack, slide the shelves into the rack and secure them to the rack 
using eight screws, 1/4 inch minimum length. 
Wall Mount 
At this point in the installation process, there should be a backboard securely fastened to 
the wall and mounting screws partially inserted into the backboard.  See Link WTS – Link 
3000 MCU: Installation
 for more information. 
To attach the shelves to the wall: 
1.  Remove all cards from the shelf.  Do not mount the shelf with cards installed. 
 
Cards contain components that may be damaged by electrostatic discharge.  
Before handling any of the cards, attach the grounding strap (included in the 
Administration Kit) to your wrist, and attach the other end of the strap to 
ground.  Handle cards only by their edges.  Do not touch connector contact 
areas.  Do not lift cards by any of the components.  Do not lay cards down on 
their component sides.  When laying a card down, place it component side 
up, on top of the anti-static bag in which it was shipped. 
2.  Position the MCS300 so that the six mounting screws are aligned with the six 
keyhole openings in the back of the shelf. 
3.  Slide the shelf down onto the screws to lock the shelf into place.  Check that all 
six screws are properly locked. 
4.  Tighten all six screws fully.   
Part Number: 72-0059-06-E.doc 