Omnia Industries TV Cables 6FM 用户手册

下载
页码 130
 
Omnia 6 Use and Installation Guide – Version 1.00a
 
97
97
few seconds, the front panel's confirmation of the time change may lag by a few seconds. 
Another use of the one way script possibility (although not strongly recommended) is the remote 're-
booting' of the Omnia. In that special case, there would be no Go High script entry. The Go Low script for 
that function would simply read:  warmboot   
Remote re-booting of the unit carries with it several caveats: 
• 
There will be a loss of audio while the system restarts. Analog and composite audio will continue to 
run for approximately nine seconds, and then nine seconds of no audio will elapse while the DSP code 
is reloaded.  
• 
If Omnia Remote Control is connected by a modem or direct serial connection at the time, it will be 
disconnected. Manual intervention will be required to reconnect. 
• 
If Omnia Remote Control is connected by Ethernet at the time, the meters on Omnia Remote and 
Omnia front panel will freeze. However, when the Omnia Remote control session is disconnected, 
normal Omnia front panel operation will be restored. Manual intervention will be required to restart 
Omnia Remote Control. 
• 
If you have not saved the System or Trigger Script settings, they may be permanently lost.