Omni Group Step Top Wood Stove 57ST-ACC 用户手册

下载
页码 52
Page  2
7038-159D
November 28, 2011
R
5700 Step Top Wood Stove Series ACC
Hearth & Home Technologies welcomes you to our tradition 
of  excellence!    In  choosing  a  Quadra-Fire  appliance,  you 
have our assurance of commitment to quality, durability, and 
performance.
This  commitment  begins  with  our  research  of  the  market, 
including  ‘Voice  of  the  Customer’  contacts,  ensuring  we 
make  products  that  will  satisfy  your  needs.  Our  Research 
and  Development  facility  then  employs  the  world’s  most 
advanced  technology  to  achieve  the  optimum  operation 
of  our  stoves,  inserts  and  fi replaces.   And  yet  we  are  old-
fashioned  when  it  comes  to  craftsmanship.    Each  unit  is 
meticulously  fabricated  and  gold  and  nickel  surfaces  are 
hand-fi nished for lasting beauty and enjoyment.  Our pledge 
to quality is completed as each model undergoes a quality 
control inspection.      
We  wish  you  and  your  family  many  years  of  enjoyment  in 
the  warmth  and  comfort  of  your  hearth  appliance.  Thank 
you for choosing Quadra-Fire.
and Welcome to the Quadra-Fire Family
!
NOTE:  Clearances may only be reduced by means 
approved by the regulatory authority having jurisdiction
 
SINGLE WALL PIPE 
12.5 (318) 10.5 (267) 25.5 (648) 15 (381)  2 (51)  12 (305)  45 (1143)  N/A
DOUBLE WALL PIPE 
9.5 (241) 7.5 (191) 25.5 (648) 15 (381)  2 (51)  12 (305)  45 (1143)  N/A
INSTALLATION:  HORIZONTAL WITH MINIMUM 2 FT VERTICAL OFF STOVE TOP
INSTALLATION: HORIZONTALE AVEC 609mm VERTICAL MINIMUM DU HAUT DU POÊLE
SINGLE WALL PIPE 
9.5 (241) 7.5 (191) 25.5 (648) 15 (381) 
45 (1143) 18 (457)*
DOUBLE WALL PIPE 
9.5 (241) 7.5 (191) 25.5 (648) 15 (381) 
45 (1143) 13 (330)
SINGLE WALL PIPE 
9.5 (241) 7.5 (191) 25.5 (648) 15 (381)  2 (51)  12 (305)  45 (1143) 18 (457)*
DOUBLE WALL PIPE 
9.5 (241) 7.5 (191) 25.5 (648) 15 (381)  2 (51)  12 (305)  45 (1143) 13 (330)
INSTALLATION: ALCOVE - Six inch (6 inches) (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 HT** listed factory-built 
Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.) Maximum depth of Alcove shall be no more than 48 
inches (1219mm) with a minimum height of  79.25 inches (2013mm) from floor to bottom of ceiling and the referenced clearances.
(**In Canada must comply with Standard CAN/ULC-S629-M87 for the 650
o
C Factory-built chimney.)
(**Au Canada doit conformer a CAN/ULC-S629-M87 la norme pour 650
o
C cheminée bâtit en usine.)
DOUBLE WALL PIPE 
     
10.5 (268)     8.5 (216) 25.5 (648) 15 (381)  N/A 
N/A 
45 (1143)  *
 
 
*
 SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTED
SPÉCIFICATIONS DE LA VENTILATION:
MUR  SIMPLE:  De  six  (6  inches)  (152mm)  de  diamètre  le  connecteur  de  conduit  de 
minimum d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en usine 
UL103HT* de Classe "A", adéquate pour usage avec les combustions solides, ou une 
cheminée de briques, avec espaces libres référés.
MUR DOUBLE: De six (6 inches) (152mm) de diamètre, le connecteur du conduit d'air 
isolé pour mur double avec une cheminée bâtit en usine UL103HT* de Classe "A:, ou 
une cheminée de briques, avec espaces libres alloués.
MAISON  MOBILE:    Utiliser  un  conduit  de  mur  double  par  Dura-Vent  DVL,  Selkirk 
Metalbestos  DS  ou  Security  DL.  Doit  être  équipé  d'un  arrêt  d'étincelle.  Utiliser  les 
espaces libres pour mur double comme mentionné ci-bas.
MIN CLEARANCES TO COMBUSTIBLE MATERIALS: Inches & (Millimeters)
NOTE:  All "A" , "C" and "F" Dimensions are to inside diameter of flue collar.
LISTED ROOM HEATER, SOLID FUEL TYPE.   
ALSO FOR USE IN MOBILE HOMES.  (UM) 
84-HUD .  "For Use with Solid Wood Fuel Only" 
1445 N. Highway, Colville, WA 99114
www.quadrafire.com
Install  and  use  only  in  accordance  with 
manufacturer's 
installation 
and 
operating 
instructions.  Contact local building or fire officials 
about  restrictions  and  installation  inspections  in 
your  area.  Do  not  obstruct  the  space  beneath 
heater.
SUITABLE FOR MOBILE HOME INSTALLATION
WARNING - For Mobile Homes
:  Do not install in 
a  sleeping  room.   An  outside  combustion  air  inlet 
must be provided and unrestricted while unit is in 
use.    The  structural  integrity  of  the  mobile  home 
floor,  ceiling  and  walls  must  be  maintained.    The 
stove needs to be properly grounded to the frame 
of  the  mobile  home.    Components  required  for 
mobile  home  installation:    Outside  Air  Kit,  Part 
Number OAK-ACC.
Refer  to  manufacturer's  instructions  and  local 
codes  for  precautions  required  for  passing 
chimney through a combustible wall or ceiling and 
maximum offsets.
Inspect  and  clean  chimney  frequently  -  Under 
Certain Conditions of Use, Creosote Buildup May 
Occur Rapidly.
Do  not  connect  this  unit  to  a  chimney  serving 
another appliance.
Optional  Components:    Optional  Blower,  Part 
BK-ACC.
Electrical Rating:  115 VAC, 1.2 Amps, 60 Hz.
Route  power  cord  away  from  unit.    Do  not  route 
cord under or in front of appliance.
DANGER: Risk of electrical shock.  Disconnect 
power supply before servicing.
Replace  glass  only  with  5mm  ceramic  available 
from your dealer.
Do  not  use  grate  or  elevate  fire.    Build  wood  fire 
directly on hearth.
Do  not  overfire  -  if  heater  or  chimney  connector 
glows, you are overfiring.
OPERATE ONLY WITH DOORS CLOSED
Open only to add fuel to the fire.
Do NOT operate before fully assembling 
components.
WARNING: Only used approved wood fuel listed 
in owners manual. Burning any other fuel will void 
warranty.
CAUTION
:
 
U.S. ENVIRONMENTAL PROTECTION AGENCY - 
Certified to comply with July 1990 particulate 
emission standards.
2011  2012  2013  Jan.  Feb.  Mar.  Apr.  May  June July  Aug. Sept. Oct.  Nov.  Dec.
PREVENT HOUSE FIRES
   
FLOOR PROTECTION
:
Floor protector must be a 1 inch min. thickness, ("k" value = 
.49
, R value = 0.59) non-co
mbustible material or equivalent, 
extending beneath heater and to front/sides/rear as indicated 
on  the  diagram  below.  Exception:  Non-combustible  floor 
protections must extend beneath the flue pipe when installed 
with horizontal venting and extend 2 inches (51mm) beyond 
each side.  
Report / Rapport
#061-S-73-6.2
TESTED TO:/ TESTÉ À:
   UL 1482-96,  ULC S627-00
HOT  WHILE  IN  OPERATION  DO  NOT  TOUCH,  KEEP  CHILDREN  AND  CLOTHING  AWAY.  CONTACT  MAY  CAUSE  SKIN  BURNS.    KEEP 
FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS
VENT SPECIFICATIONS:
SINGLE WALL: Six inch (6 inches) (152mm) diameter, minimum 24 MSG black 
or  blued  steel  connector  pipe,  with  a  listed  factory-built  UL103HT*  Class  "A" 
chimney,  suitable  for  use  with  solid  fuels,  or  a  masonry  chimney,  and  the 
referenced clearances.
DOUBLE WALL: Six inch (6 inches) (152mm) diameter, listed double wall air 
insulated connector pipe with listed factory-built UL103HT* Class "A" chimney, 
or  a masonry chimney and the referenced clearances
MOBILE HOME:  Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos 
DS or Security DL double wall connector pipe. Must be equipped with a spark 
arrestor.  Apply double wall clearances below when installing unit.
R
7038-162D
CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT 
PEUT CAUSER DES BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR 
L'ÉTIQUETTE ET LES INSTRUCTIONS.
ATTENTION:
APPAREIL DE CHAUFFAGE DE PIÈCE, DE TYPE DE 
COMBUSTIBLE SOLIDE, POUR USAGE DANS LES 
MAISONS MOBILES. (UM) 84 HUD. "Pour Usage Avec 
Bois Solide Seulement"
Installez  et  utilisez  en  accord  avec  les  instructions 
d'installation  et  d'opération  du  fabricant.  Contactez  le 
bureau de la construction ou le bureau des incendies au 
sujet des restrictions et des inspections d'installation dans 
votre voisinage. Ne pas obstruez l'espace en dessous de 
l'appareil.
CONVIENT POUR UNE INSTALLATION MAISON MOBILE
AVIS - Pour Les Maisons Mobiles:  Ne pas installer dans 
une  chambre  à  coucher.  Un  tuyau  extérieur  de 
combustion  d'air  doit  être  installé  et  ne  doit  pas  être 
obstrué  lorsque  l'appareil  est  en  usage.  La  structure 
intégrale  du  plancher,  du  plafond  et  des  murs  de  la 
maison  mobile  doit  être  maintenue  intacte.  L'appareil  de 
chauffage  doit  être  fixé  à  la  charpente  de  la  maison 
mobile.  Les  composants  requis  pour  l'installation  des 
maisons mobiles: Assemblage d'air extérieur, Numéro de 
Pièce OAK-ACC.
Référez  vous  aux  instructions  du  fabricant  et  des  codes 
locaux  pour  les  précautions  requises  pour  passer  une 
cheminée  à  travers  un  mur  ou  un  plafond  combustibles, 
et les compensations maximums.
Inspectez  et  nettoyez  la  cheminée  fréquemment.  Sous 
certaines  conditions,  il  se  peut  que  la  créosote 
s'accumule rapidement.
Ne pas connecter cet appareil à une cheminée servant un 
autre appareil.
Composants  Optionnels:  Ventilateur  Optionnel,  Pièce 
BK-ACC.
Puissance Électrique: 115 VAC, 1.2 Amps, 60 Hz.
Éloignez le fil électrique de l'appareil. Ne pas faire passer 
le fil électrique au dessus ou en dessous de l'appareil.
DANGER:  Il  y  a  risque  de  décharge  électrique.  
Déconnectez le fil électrique de la prise de contact avant 
le service.
Remplacez  la  vitre  seulement  avec  une  vitre  céramique 
de 5 mm disponible chez votre fournisseur.
N'élevez  pas  le  feu.  Bâtissez  le  feu  de  bois  directement 
sur l'âtre.
Ne pas surchauffer. Si l'appareil de chauffage ou le tuyau 
de cheminée rougissent, vous surchauffez.
Opérez  l'appareil  seulement  lorsque  la  porte  de 
chargement  est  fermée.  Ouvrez  la  porte  seulement 
lorsque vous devez ajouter des combustibles dans le feu.
PRÉVENTION DES FEUX DE MAISON
PROTECTION DU PLANCHER:
Le  protecteur  de  plancher  doit  être  d'un  minimum  de  1  inch 
(25mm) d'épaisseur, ('k" value = .49, R value = 0.59) de matériel 
incombustible ou équivalent, s'étendant du dessous de l'appareil 
de  chauffage  à  l'avant,  aux  cotés  et  à  l'arrière  comme  indiqué 
sur  le  diagramme  suivant.  Exception:  Les  protections 
incombustibles  du  plancher  doivent  s'étendre  en  dessous  du 
conduit  de  cheminée  lorsqu'installées  avec  une  ventilation  à 
l'horizontale et s'étendre de 2 inches (51mm) de chaque côté.  
ESPACES LIBRES MIN DES MATÉRIAUX COMBUSTIBLES: 
En Pouces & (millimètres)
NOTE:  Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur 
de l'entrée du conduit.
BACKWALL/SIDE
WALL/
MUR 
ARRIÈRE/MUR 
DE CÔTÉ 
90  OFF TOP UP & OUT 
CEILING CLEARANCE/
ESPACE LIBRE DU 
DESSUS DE 
L'APPAREIL AU 
PLAFOND AVEC 90  DE 
COURBURE 
CORNER 
INSTALLATION/
INSTALLATION 
DU COIN 
ALCOVE TOP 
VIEW /
VUE DU HAUT DE 
L'ALCÔVE 
ALCOVE SIDE 
VIEW / 
VUE DE CÔTÉ 
DE L'ALCÔVE
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE
CONDUIT DU MUR SIMPLE
CONDUIT DU MUR DOUBLE
INSTALLATION:  90
ELBOW OFF TOP OF STOVE THROUGH BACKWALL
INSTALLATION:  90
DU COURBURE AU DESSUS DE HAUT DU POÊLE A TRAVERS LE MUR ARRIERE
INSTALLATION: ALCÔVE - De six (6 inches) (152mm) de diamètre, le connecteur du conduit d'air isolé pour mur double avec une cheminée bâtit en usine 
UL103HT** de Classe "A", ou une cheminée de briques. (Les maisons mobiles doivent être équipées d'un arrêt d'étincelle). La profondeur maximum de 
l'alcôve ne doit pas être de plus de 48 inches (1219mm) avec une hauteur minimum de 45 inches (1143mm) la distance entre du plancher et plafond inférieur, 
et des espaces libres alloués. 
CONDUIT DU MUR DOUBLE
A
B
C
D
E
F
E
F
G
H
C
D
G
A
B
16" from glass
8"
USA
Fuel loading door
33-5/8”
minimum
45-7/8”
minimum
CANADA
203mm (8")
203mm
(8")
203mm
(8")
457mm (18")
1419mm 
(55-7/8")
minimum
1092mm (43")min
Manufactured by:
Fabriqué par:
INSTALLATION: FULL VERTICAL      INSTALLATION: ENTIÈREMENT VERTICALE 
CONDUIT DU MUR DOUBLE
SERIAL NO. / NUMÉRO DE SÉRIE
007007
O-T L
Tested and 
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
C
US
5700 Step Top ACC
STOVE TO CEILING CLEARANCE/
ESPACE LIBRE DU POÊLE AU 
PLAFOND 
CONDUIT DU MUR SIMPLE
CONDUIT DU MUR SIMPLE
CONDUIT DU MUR DOUBLE
Ne mettez PAS le poêle en marche tant que tous les 
composants n’ont pas été entièrement assemblés.
ATTENTION: Seulement utilisé carburant approuvé 
indiquée dans le manuel des propriétaires. La 
combustion d'autres combustibles annulera la garantie.
Made in U.S.A. 
of US and 
imported parts.
Fabriqué aux États-Unis-d’Amérique par 
des pièces d’origine américaine et pièces 
importées.