Nissin Di866 用户手册

下载
页码 11
19
20
21
22
When setting Di866 to the slave function, the zoom setting system is 
automatically  set  for  the  Manual  Zoom  at  24mm  position.  The 
zooming  position  can  be  selected  manually  to  any  other  position 
available.In  this  mode,  the  auto-off  timer  is  recommended  to  set  at 
60min. or be cancelled (off). The sensing angle of the slave sensor is 
100 approx.
In this case, reset this F. Stop on you camera.
As for the traditional type film cameras, no ISO information or F. Stop 
information is transferred by the camera.  In this case, set ISO value at the 
Advanced function page of Di866.
The flash light is automatically controlled by the photo sensor built-in the flash 
unit instead of TTL metering. Select your desired F. Stop on Di866 and set this 
F. Stop on your camera. The intensity of flash light is automatically controlled 
for the most proper exposure within the certain area of distance.
Set the camera mode, to M or Av on your camera.
Set the mode on Di866. From the 6 icons screen, select
         M/Av and set       .
Select        Av and set       .
F. Stop is displayed in the screen in accordance with the 
ISO setting on the camera.
Select          your desired F. Stop and set       on the flash 
unit.
Press on/off switch to lock the value. (Press it again to 
release the lock)
Set the same F. Stop on your camera.
The display screen shows the F. Stop selected, the 
camera-subject maximum distance for the proper 
exposure and the focal length set on the camera.
The flash light is automatically controlled within the 
distance area.  The shortest distance for the proper 
exposure is approximately 1.0m(3ft.) from the camera to the subject.  
The distance varies by changing the focal length and F. Stop set on Di866.
This Av. mode of Di866 is not coupled with camera’s aperture setting. The 
aperture setting on the flash unit is not controlled by the camera.
When changing the ISO setting on the camera, the F. Stop of the flash unit 
is automatically reset for such corresponding ISO value.
Av. Mode Operation
Set
Set
Set
The mode to be set on the camera: 
Advanced custom setting is prepared in this mode.
.
ADVANCED CUSTOM SETTING
page 14
page 19
page 15
Sub Flash Function
Manual Zoom Setting
Universal Slave Function
Setting of Master and Slave flash:
Setting Master flash: 
The master flash to be set is one unit only.
Place the master flash on the 
camera and switch it on, and set to 
Manual function mode or set to the 
camera’s built-in flash on. Make 
sure which mode you chose, digital 
pre-flash flash system or analogue flash system.
Setting Slave flash Di866: 
Multiple numbers of flashes can be set. Switch 
Di866 on and select the appropriate slave 
system, either SD or SF. 
When flash is set to the slave function, the red 
LED starts blinking every 2 seconds showing the 
slave function is in order. Make sure the mode 
you set, SD or SF which should couple with the master 
flash system.                                                                                                                                   
Set slave flash at any place and direct the flash head as you 
desire. Slave sensor in the slave flash is facing to the camera or 
to the master flash.
Use the included flash stand. Place Di866 on to the flash stand 
which can be placed either on a flat place or on the tripod by the 
screw.
NOTE
Metal type accessory shoe is not recommended since it may give electric damage on 
the electrical contact of the flash hotshoe.
!
Advanced custom setting is prepared in this mode. 
.
ADVANCED CUSTOM SETTING
page 14
page 15
Sub Flash Function
Manual Zoom Setting
Universal Slave Function
Di866 has a universal wireless remote flash system as a slave unit.
You can enjoy creative flash photography with multiple lightings from the 
various directions. 2 slave modes are provided in accordance with the flash 
system of the master flash.
Slave Digital (SD) for digital pre-flash system and Slave Film (SF) for an 
analogue flash system are available.
SD: In this mode Di866 synchronizes to pre-flash system. The master flash is to 
be set at TTL/ETTL II mode.
SF: In this mode Di866 synchronizes to the traditional single flash system. The 
master flash is to be set at manual mode. Studio strobe lighting system 
synchronizes to this mode. This mode also responds to open flash and to 
traditional type flash unit in the market.
How to find SD or SF?
Select SD on your slave flash and release your camera’s shutter to flash your 
master flash. The slave flash flashes if the Master flash is SD, and does not 
flash if the Master flash is SF. If your slave flash is set at SF, it flashes against 
both of SF and SD flash system.
To set Di866 to the salve function mode, move cursor
        to Slave line at Advanced function page and 
continuously select          SD or SF in accordance with the 
system of the master flash you set.
page 19
Press the set       button or wait for 8 sec. to return to M 
function screen.
Set
or
v
In additional to the Manual power mode, the universal slave function 
supports Av operation mode. 
Setting Slave flash: Select the slave mode SD or SF and set the 
desired F.stop and ISO speed on the Slave flash. As for setting 
Master flash, follow to the instruction manual in the Universal slave 
page at Manual power operation --- Page 20.