NEC 2400 PX 用户手册
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
NDA-24297, Issue 1
Page 103
Blind Transfer To Station
B-18
Programming
STEP 1:
ASYD
- System 1, Index 69, Bit 0:
Processing for a case where the transfer destination station does not answer the call within a
predetermined period of time. 0/1 = the transferring station is recalled/the transfer destination station is
continuously rung, or if the Call Forwarding - Don’t Answer is set at the destination station, Call
Forwarding - Don’t Answer is executed. Index 247: Assign the timer value of No Answer Timer for
Blind Transfer to Station.
predetermined period of time. 0/1 = the transferring station is recalled/the transfer destination station is
continuously rung, or if the Call Forwarding - Don’t Answer is set at the destination station, Call
Forwarding - Don’t Answer is executed. Index 247: Assign the timer value of No Answer Timer for
Blind Transfer to Station.
STEP 2:
ASFC
- Assign the following data to the SFC of the station:
SFI = 103:
Assign the timer value of No Answer Timer for BLIND TRANSFER TO STATION.
RES:
0/1 = Index 140 / Timer value assigned by ASYD, SYS-1, Index 247
0 = Index 140
1 = Index 247
1 = Index 247
Also, when ASYD, SYS-1, Index 69, b0 = 1 has been assigned, assign the following data to the SFC of
the station:
SFI = 104:
the station:
SFI = 104:
Processing in a case when the transfer destination station does not answer within a
predetermined period of time.
predetermined period of time.
RES: 0/1 =
The transfer destination station is continuously rung / Call Forwarding - Don’t Answer
is executed if it is set at the transfer destination station.
is executed if it is set at the transfer destination station.
FCCS Programming
No unique programming is required for the FCCS network.
Note:
System timers may be set on a network basis in ASYDN.