National Instruments NI 1450 Series 用户手册

下载
页码 83
Chapter 2
Setup and Configuration
2-10
ni.com
The NI 1450 ships with a factory-installed startup program that, when the 
NI 1450 is connected to a camera and powered on, acquires images and 
displays them on the monitor. If these images from the camera display on 
the monitor, continue to the 
 section. If the images from the camera are not displayed on the 
monitor, refer to Appendix A, 
Figure 2-3.  Wiring Power to the NI 1450
Connecting to a Separate Main Supply
If you are using a power supply other than the NI desktop power supply, 
use this section to connect power to the NI 1450.
Caution
Do not connect the NI 1450 main power to a source other than 24 VDC ±10%. 
Do not connect the NI 1450 isolated power to a source less than 5 VDC or greater than 
30 VDC. Doing so could damage the NI 1450. 
1
4-Position Power Connector
2
NI Desktop Power Supply
3
Power Supply Cord (to Outlet)
1
3
To Outlet
2