National Instruments Car Stereo System 320571-01 用户手册
Chapter 2
NI-DSP Analysis VI Reference
NI-DSP SRM for LabVIEW for Windows
2-31
Part 3: NI-DSP Function Reference
DSP Exponential Window
Applies an exponential window to the input
sequence X. If Y represents the output
sequence Exponential{X}, the elements of
Y are obtained using the formula:
sequence X. If Y represents the output
sequence Exponential{X}, the elements of
Y are obtained using the formula:
y
i
= x
i
exp(a * i)
for i = 0, 1, 2, … , n-1,
a =
ln |f|
n - 1
n - 1
,
where f is the final value, and
n is the number of elements in X.
You can use the Exponential Window VI to analyze transients.
X is a DSP Handle Cluster that indicates the memory buffer on the DSP board that contains the input
signal array.
signal array.
Note: The operation is performed in place and the input array X is overwritten by the output
Exponential {X}.
final value defaults to 0.10.
Exponential {X} is a DSP Handle Cluster that is identical to X, but with the results of Exponential {X}
already stored in the memory buffer on the DSP board.
already stored in the memory buffer on the DSP board.
error in (no error) contains the error information from a previous VI. If an error occurs, it is passed out
error out and no other calls are made.
error out and no other calls are made.
error out contains the error information for this call.